POUNDING RESPONSE OF THREE ADJACENT BUILDINGS UNDER NEAR-FAULT STRONG GROUND MOTION AND ITS EFFECT ON SEISMIC BEHAVIOR OF INTERIOR AND EXTERIOR BUILDINGS
Author(s):
Abstract:
In this investigation, a simple model of building in series, including 3-, 2-, and 3-story adjacent buildings, excited by the horizontal and vertical components of faultnormal pulse and fault-parallel displacement with dierent magnitudes and time lags, is considered. Each story of the buildings consists of a rigid beam connected to two axially rigid mass-less columns by nonlinear rotational springs and linear rotational dashpots. To determine the pounding force, the non-linear viscoelastic model was chosen. The ground motion was described by fault-normal pulse and fault-parallel permanent displacement, and their amplitudes and duration were selected consistent with the variables that described nearfault motions. An important physical characteristic of the selected pulse and displacement is large initial velocity associated with onset of these motions, and it is proportional to the stress drop on the fault. It is assumed that the buildings are near the fault, and that the longitudinal axis of the buildings (x-axis) coincides with the radialdirection(r-axis)ofthepropagationofwavesfrom the earthquake source, so the absolute displacements of the bases of columns are dierent due to the wave passage. The system of equations of motion was solved by the fourth-order Runge-Kutta method due to its selfstarting feature and the long-range stability. For the considered model, the results indicate: (1) impact force can lead to increasing the maximum storey shear force. Thisamplicationcanbeseenpredominantlyinexterior or end buildings which experience one-sided impacts, compared with interior building which experiences twosidedimpacts; (2)byincreasinginitialgapsize,themaximum impact force will not decrease necessarily. Depending on the period of buildings, initial gap size, and material nonlinearity, the maximum impact force can occur between the left and middle buildings or between the middle and right buildings; (3) for linear material under fault-normal pulse with magnitudes 5, 6, and 7, the expected maximum impact force and the minimum distance required to avoid pounding would be equal to 10, 58, 100 MN, and 10, 30, 50 cm, respectively; (4) for nonlinear material, the corresponding values would be equal to 10, 40, 45 MN, and 10, 20, 30 cm, respectively
Keywords:
Language:
Persian
Published:
Sharif Journal Civil Engineering, Volume:33 Issue: 1, 2017
Pages:
113 to 123
magiran.com/p1719762
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یکساله به مبلغ 1,390,000ريال میتوانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
- حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران میشود.
- پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانههای چاپی و دیجیتال را به کاربر نمیدهد.
In order to view content subscription is required
Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!