INVESTIGATION INTO THE EFFECT OF FRICTION PENDULUM SYSTEMS ON SEISMIC DAMAGE REDUCTION OF SUBSTATION EQUIPMENT

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:

Substation damage, and consequently electricity cut-off, have been always one of the costly earthquake disastrous outcomes. In the present study, a 2-item set of equipment, including capacitive voltage transformer (CVT) adjacent to a lightning arrester (LA) known as vulnerable instruments existing in substations, is aimed to seismically strengthen by isolation strategy. The isolator device considered in the present study is a single friction pendulum system (FPS) which possesses sliding and re-centering mechanisms integrated in one unit. In addition, CVT and LA instruments are cable-connected as well. Since interaction of conductors between equipment subjected to earthquakes is a challenge for seismic design of substations, it is prudent to design the cable-connected system with sufficient cable slackness.By taking advantage of incremental dynamic analysis (IDA) and defining an appropriate damage state, equipment seismic response is evaluated. Many measures of earthquake ground motion intensity, rather than PGA, have been examined. Finally, it is decided that the peak ground displacement (PGD) can better represent the equipment seismic response among all other alternative measures. Afterwards, porcelain insulator breakage (which outnumbers any other reported failure modes of CVT and LA) and breakage of conductor terminal pads are taken as the two main failure mechanisms of 2-item set of equipment. Moreover, the influence of the gap between FPS stoppers is one of the most prominent variables considered in the present study. The rationale behind the decision refers to pounding of slider against stoppers, which seemes to be a matter of concern.The IDA curves of the non-isolated 2-item set of equipment revealed that LA is much more susceptible to failure. In order to evaluate the isolation effect on the seismic performance of the 2-item set of equipment, two different cases are supposed: A. Base isolation of CVT while LA is fixed-base; B. Base isolation of LA while CVT is fixed-base. Case A was found to be much more suitable than case B to enhance the seismic performance. Eventually, it is concluded that FPS isolator has the potential to decrease flexural stresses caused by intense ground motions, and this could be enhanced by widening the gap between stoppers of isolator.

Language:
Persian
Published:
Sharif Journal Civil Engineering, Volume:33 Issue: 1, 2017
Pages:
55 to 62
magiran.com/p2007158  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!