Evaluation of Occupational Radiation Status and Validity of Individual Dose and Eye Lens Assessment Using Single Film Dosimeter for Angiographic Staff in Iran

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background and Aim

In angiography, the lens of the eye may be exposed to radiation and cause cataracts. In Iran, at present, only a single film dosimeter is used under the lead-apron to evaluate individual doses. The aim of this study was to investigate the status of occupational radiation as well as the validity of measuring the dose of the whole body of individuals and eye lenses using a single film dosimeter.

Materials and Methods

In this study, the dose of the whole body and eye lenses were measured using a combination of film and thermoluminescence dosimeters for 35 employees of the angiography departments in three selected hospitals under the auspices of Tehran University of Medical Sciences(TUMS). To measure the eye lens dose, three thermoluminescence dosimeter pellets were used on the forehead, and left and right eyes; and to measure the whole body dose using the two-dosimetry method, a TLD card mounted on the chest and on the lead apron and a film dosimeter on the chest and under the lead apron were used.

Results

The angiography personnelchr('39')s monthly dose mean of the eye lenses and the whole body were approximately 240.6±6.4 μSv and 120.3±3.3 μSv, 
respectively(the corresponding amount for the annual dose is less than the levels recommended by international authorities). In addition, the dose ratio of film badge to whole body and eye  lens was 0.35 and 0.51, with correlation coefficients of 0.97 and 0.5, respectively. Also, the ratio of eye lens dose to depth dose(TLD) on the lead apron was 1.18 with a correlation coefficient of 0.79.

Conclusion

Using a single film dosimter under the lead apron to estimate the dose of the whole body is almost accurate but this dosimeter alone is not suitable for the assessment of the lens dose of the eye; it is necessary to use an individual dosimeter on the lead apron.

Language:
Persian
Published:
Journal of Payavard Salamat, Volume:14 Issue: 5, 2021
Pages:
404 to 412
magiran.com/p2245343  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!