Investigating the Practical Applications of the Frequency Response of the ‎Transformers Extracted Using the Lightning Impulse Test Results

Author(s):
Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
The Lightning Impulse (LI) test is performed on newly manufactured power transformers as a routine Factory Acceptance Test (FAT). A well-known Marx Impulse Generator (MIG) is utilized in this test. The setting of the MIG can be changed to obtain standard LI wave shape. Since various power transformers may have windings with dissimilar designs, different MIG settings may be required for each transformer. The accurate computer simulation of the LI test circuit can give help in finding the optimum setting of the MIG. The Frequency Response (FR) of the power transformer impedance is required in such simulations. Similarly, the transformer FR is required in calculating the Transient Recovery Voltage (TRV) across the contacts of the Circuit Breakers (CB) in the case of the Transformer Limited Fault (TLF). The accurate calculation of such TRVs has a great importance in selecting the proper rating for CBs. The FR of the transformer can be measured directly with network analyzers or some other conventional test instruments. However, performing an additional test to obtain the transformer FR imposes extra cost and efforts. Alternatively, it can be achieved by using the routine LI test results which is readily available. Fortunately in both mentioned applications similar connections are required for transformer terminals. In this paper, the procedure to extract the transformer FR using the LI test results is presented. Then, the validity of such extracted FRs is investigated by comparing them with the ones measured by conventional test instruments. As an innovation, the extracted transformer FRs are used in the LI test circuit simulation and the accuracy of the method is examined by experimental works. Moreover, the application of the extracted FR in TLF TRV calculation is investigated as well. The validity of the all presented theoretical concepts are evaluated using the experimental test results on a real large power transformer.
Language:
English
Published:
Journal of Operation and Automation in Power Engineering, Volume:10 Issue: 3, Autumn 2022
Pages:
206 to 213
magiran.com/p2421376  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!