Quantitative Assessment of Conventional and Modern De-Noising on Nuclear Medicine Images

Message:
Abstract:
Introduction
One of the major problems in the development of nuclear medicine images is the presence of noise. The noise level in nuclear medicine images is usually reduced by the analysis of imaging data in a Fourier transform environment. The main drawback of this environment belongs to low signal to noise ratio in high frequencies because removing noise frequencies may remove data and times information as well. This problem becomes more serious when the most important signals are non-stationary. The aim of this research is to evaluate the effect of wavelet transform on nuclear medicine image.
Materials And Methods
A brain phantom-like Hoffman phantom with 4 layers was used. Planar images were acquired from the phantom, with a total count of 107 (as reference image) and from each layer separately. The counts of planar images in each layer were increased from 100 to 700 kilo counts in seven steps. Different levels of white (Gaussian) noise was added to the reference images using MATLAB software. Simulation images using Simset software and NCAT phantom were also produced. Wavelet transform, Butterworth, Metz, Hanning(3*3) and Wiener filters were applied on all images. The Universal Image Quality Index (UIQI) was used to evaluate the image quality.
Result
Wavelet transform can increase the value UIQI (UIQI = 0.7352). The effect of wavelet transform on the improvement of image quality is much better than Butterworth (UIQI = 0.3556) and Metz (UIQI = 0.3493) but almost the same as the effect of Wiener (UIQI = 0.7626) and Hanning (3*3) (UIQI = 0.8017). Discussion and
Conclusion
Although wavelet transform is not the best method of reducing noise level, but its use can reduce the noise level like filters do. Assessment of commonly used thresholds as well as new design of a special threshold for wavelet transform in nuclear medicine images can improve the performance of this transform.
Language:
Persian
Published:
Iranian Journal of Medical Physics, Volume:3 Issue: 10, 2006
Pages:
35 to 44
magiran.com/p415119  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!