به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت

فهرست مطالب ahmadreza yazdanbakhsh

  • Rraheleh Kafaei, Ahmadreza Yazdanbakhsh, Mohsen Sadani, Nadali Alavi *
    For the first time, the ability of a Microbial Fuel Cell (MFC) to produce value-added products from the high content of oily kitchen waste was evaluated. A Single-chamber, air-cathode MFC containing 30% solids was designed for evaluation of the rate of biohydrogen and bioelectricity production. Food wastes were studied in four states: oil-free (0%), containing 3% oil, 6%, and 9% oil during 30 days of operation. Experiments showed with increasing the amount of oil, the amount of biohydrogen produced increased from 0 to 6% of the oil, and with the addition of 9% of oil, no significant change was observed in the biohydrogen production rate. The average daily production of biohydrogen for 0, 3, 6 and 9% of the oil was estimated at 42.5, 58.7, 69.6 and 70.1 mL per day, respectively, which showed that adding oil up to 6% could increase the efficiency of the system for biohydrogen production. On the other hand, with the increase in the amount of oil, the production of bioelectricity decreased, so that the maximum output voltage was recorded for the fourth day of zero state: 472 mV, and the lowest voltage on most of the days recorded for 9% of oil. The results of Chemical Oxygen Demand (COD) removal showed with increasing the amount of oil, although the amount of initial COD increased, the amount of COD removal decreased, which is consistent with the process of electricity production. Volatile fatty acids including acetate, butyrate, and propionate were other valuable products of the system, although the accumulation of VFA was indicated as an inhibitor for biohydrogen production The results showed kitchen waste without oil separation can be used as a useful substrate in MFC systems to produce value-added products, in this way, sewage pollution by oil resulted from food waste could be prevented.
    Keywords: Biohydrogen, Bioelectricity, Microbial fuel cell, Food waste, Volatile fatty acids, Sustainable environment}
  • Zahra Jamshidinasirmahale, Ahmadreza Yazdanbakhsh*, Mohamadreza Masoudinejad, Nadali Alavi Bakhtiarvand
    Background

    Anaerobic co-digestion (AcoD) of various wastes is a suitable method for the removal of contaminants and biogas production. The first aim of this study was to determine the optimal ratio of landfill leachate (LL) and sewage sludge (SS) for AcoD, and the second one was to evaluate the effect of
    pre-ozonation of the mixture on AcoD.

    Methods

    The LL and SS samples were taken from landfill sites and municipal wastewater treatment plants (MWTPs), respectively. In the first step, five reactors were used and named R1 (100% SS), R2(100% LL), R3 (15% LL/85% SS), R4 (25% LL/75% SS), and R5 (45% LL/55% SS). Mesophilic anaerobic digestion (AD) was performed on the reactors and the optimal ratio was determined. In the second stage, the optimal mixtures were subjected to an ozonation process before AcoD.

    Results

    The results of the first stage showed that the highest efficiency removal of the total solids (TS), volatile solids (VS), and chemical oxygen demand (COD), and the highest biogas production belonged to R3 digester, containing 15% LL and 85% SS. In the second stage, the results showed that the removal efficiency of COD and VS in the ozonated sample at the dosage of 7.6 gO3/h were 29.8% and 36.6% higher than the non-ozonated sample, respectively. Furthermore, in the ozonated sample, the biogas yield and the content of methane in the gas mixture were 27% and 9% higher respectively, compared to the non-ozonated sample.

    Conclusion

    According to the results, the appropriate ratio of LL to SS and pre-ozonation of LL/SS mixture have a great impact on the performance of AcoD.

    Keywords: Sewage, Solid waste, Ozone, Anaerobic, Methane}
  • محمد رفیعی، احمدرضا یزدانبخش، حسین حاتمی، حسن جلیلوند*
    زمینه و هدف

    آلاینده نوظهور پرکلرات با توزیع جهانی، پایدار در محیط، حلالیت بالا در آب، با ایجاد تغییراتی در سطح هورمون های تیرویید، مهمترین تهدید سلامتی در عصر حاضر است. پرکلرات با نوشیدن آب یا غذای آلوده به پرکلرات وارد بدن می شود. سازمان حفاظت محیط زیست آمریکا مقدار 15 میکروگرم در لیتر به عنوان رهنمود در آب آشامیدنی ارایه نموده است. هدف از این مطالعه تعیین ارتباط بین غلظت پرکلرات در آب آشامیدنی و فراوانی بیماری کم کاری تیرویید در نوزادان می باشد.

    روش بررسی

    تعداد 238 نمونه از سامانه های آبرسانی منطقه مورد مطالعه جمع آوری شد. نمونه ها بر اساس روش های استاندارد آزمایش های آب و فاضلاب و کروماتوگرافی یونی آنالیز شدند.

    یافته ها

    نتایج این بررسی نشان داد که مشخصات کیفی آب آشامیدنی سامانه های آبرسانی منطقه مورد مطالعه در محدوده نرمال و مطابق با استاندارد است. آب آشامیدنی منطقه مورد مطالعه جزء آب های سخت طبقه بندی می شود. غلظت پرکلرات آب آشامیدنی بین 002/0 تا 009/0 میلی گرم بر لیتر تشخیص داده شد.

    نتیجه گیری

    غلظت پرکلرات در آب آشامیدنی منطقه مورد مطالعه مطابق رهنمود ارایه شده توسط سازمان حفاظت محیط زیست آمریکا است و سلامت مصرف کنندگان را مورد تهدید قرار نمی دهد.

    کلید واژگان: پرکلرات, آب آشامیدنی, کم کاری تیروئید نوزادان, دماوند}
    Mohammad Rafiee, Ahmadreza Yazdanbakhsh, Hossein Hatami, Hassan Jalilvand*
    Background

    The newfound  pollutant perchlorate, with global distribution, long-term stability in the environment, and solubility in water, is the most crucial health threat of the present era by causing changes in the level of thyroid hormones. Perchlorate enters the body by drinking water or contaminated food with perchlorate. The United States Environmental Protection Agency has provided a guideline of 15 μg/L in drinking water. This study aims to determine the relationship between the concentration of perchlorate in drinking water and the frequency of hypothyroidism in newborns.

    Methods

    238 samples were collected from the water supply network of the study area. The samples were analyzed according to the standard water and wastewater tests and ion chromatography methods.

    Results

    The results showed that the quality characteristics of drinking water in the water supply systems of the studied area are within the normal range and in accordance with the standard. Drinking water is classified as hard water in Damavand city. Perchlorate concentration of drinking water was detected to be 0.002 - 0.009 mg/liter.

    Conclusion

    The concentration of perchlorate in the drinking water of the study area is according to the guidelines of the U.S. Environmental Protection Agency and does not threaten consumers’ health.

    Keywords: Perchlorate, Drinking Water, Infant Hypothyroidism, Damavand, Fertilizers, chemical poisons}
  • Ahmadreza Yazdanbakhsh*, Mohsen Sadani, Mohammad Golaki

    The removal of formaldehyde as a toxic substance from aqueous solutions is of particular importance. In this research, a sequencing batch rotating-bed bioreactor (SBRB) was used on a laboratory scale for biodegradation of formaldehyde from synthetic wastewater. The reactor was made of plexiglas with a cylindrical shape. Kaldnes media were placed in a rotating cylindrical basket in the reactor. The effects of formaldehyde concentration (500–1500 mg/L), hydraulic retention time (HRT) (8, 15, 24 hours), and injection of hydrogen peroxide (0.1-0.5 mM) on the performance of the reactor were investigated. The results showed that in the SBRB, at an HRT of 24 hours and an inlet formaldehyde concentration of 1000 mg/L, the removal efficiencies of formaldehyde and chemical oxygen demand (COD) were 99.2% and 92%, respectively, while without rotating the bed, the removal efficiency of formaldehyde and COD was found to be 95% and 83%, respectively. By adding hydrogen peroxide at a concentration of 0.3 mM and operation of the SBRB with an HRT of 8 hours and an inlet formaldehyde concentration of 1000 mg/L, an improvement in the removal efficiency of formaldehyde and COD (4% and 22%, respectively) was observed. Accordingly, SBRB stimulation with hydrogen peroxide could be considered as a high-performance process for the removal of formaldehyde and corresponding COD at a short HRT.

    Keywords: Formaldehyde, Rotating bed, Bioreactor, Wastewater, Peroxidase}
  • Roya Radmehr, Mohammad Rafiee, Ahmadreza Yazdanbakhsh*
    Background

    Olive mill wastewater (OMW) is characterized by its high organic content and refractory compounds. The aim of this study was to evaluate and compare the efficiency of UV/O3 and UV/ acetylacetone (UV/AcAc) processes for treatment of pretreated OMW by coagulation/microfiltration (C&M) process.

    Methods

    In this study, a laboratory-scale UV plug flow reactor with ancillary equipment was fabricated. The experimental factors including initial pH (5-9), O3 dosages (1.5-4.5 g/h), and AcAc concentrations (0.01-0.03 M) were measured. For both processes, a reaction time of 120 min was considered. The effect of these variables on removal of wastewater contaminants including BOD, COD, TSS, turbidity, phenol, oil, and grease were investigated.

    Results

    Results showed that raw OMW has a high load of pollutants and very low biodegradability (BOD5/COD = 0.12). In UV/O3 process, the optimal conditions were obtained at pH 8 and ozone injection at 4 g/h. The combined C&M-UV/O3 process removed 78.75% COD, 46.66% BOD5, 90.88% total phenol, 91.78% TSS, 99.14% oil and grease, and 98.38% turbidity, with promotion of BOD5/ COD from 0.12 to 0.33. In UV/AcAc process, the optimal conditions were achieved at pH 5 and AcAc concentration of 0.03 M. The combined C&M-UV/AcAc process removed 58.75% COD, 67.58% BOD5, 38.03% total phenol, 83.50% TSS, 93.65% oil and grease, and 95.00% turbidity, with promotion of BOD5/ COD from 0.12 to 0.22.

    Conclusion

    The results showed that the UV/O3 process is completely superior to the UV/AcAc process for removal of OMW contaminants, as well as promoting the biodegradability of OMW.

    Keywords: Olive mill wastewater (OMW), Treatment, UV, O3, AcAc, Biodegradability}
  • Pouria Karimi, Ahmadreza Yazdanbakhsh*, Ali Atamaleki, Fatemeh Kariminejad, Mohammad Ahmadian, Sevda Fallah
    Background

    We aimed to conduct a meta-analysis on the concentration of potentially harmful elements (PHEs) in carrots and potatoes irrigated by wastewater and estimate non-carcinogenic health risks among adult and children consumers.

    Methods

    The health risk of PHEs concentration, including Pb, Cd, total Cr, Ni, Zn, Cu, and Fe, in the edible parts of carrot and potato irrigated by wastewater was investigated by a meta-analysis using a random-effects model (REM). Accordingly, the related articles were screened from international databases such as Scopus, Medline, and Embase.

    Results

    The meta-analysis of 32 papers (38 studies) revealed that the rank order of the most accumulated PHEs in potato was Fe (86.54 mg/kg wet weight) > Zn (30.9 mg/kg wet weight) > Cu (13.7 mg/kg wet weight) > Ni (8.42 mg/kg wet weight) > Pb (5.56 mg/kg wet weight) > Cr (3.45 mg/kg wet weight) > Cd (0.58 mg/kg wet weight). This ranking for carrot was Fe (43.36 mg/kg wet weight) > Zn (36.29 mg/kg wet weight) > Ni (13.49 mg/kg wet weight) > Cu (9.79 mg/kg wet weight) > Pb (1.84 mg/kg wet weight) > Cr (1.05 mg/kg wet weight) > Cd (0.28 mg/kg wet weight). Total hazard quotient (THQ) of PHEs was higher than 1 for potato and carrot; its rank order for potato and carrot was Cu > Pb > Cd > Ni > Fe > Zn > Cr and Cd > Pb > Cu > Ni > Fe > Zn > Cr, respectively. The Cd, Pb, and Cu had also a considerable role for consumer health risk.

    Conclusion

    According to the results, continuous monitor and control of wastewater treatment plants are necessary.

    Keywords: Wastewater, Food chain, Cadmium, Lead, Risk assessment}
  • Ahmadreza Yazdanbakhsh, Hassan Rasoulzadeh *
    Background

     The recovery of rare-earth elements (REEs) like toxic lanthanides from contaminated waters is vital because of their irreversible effects on humans and the environment.

    Objectives

     In the present research, a chitosan-imprinted nano zero-valent iron (CS@nZVI) nanocomposite was fabricated and utilized to the successful separation of Lanthanum as a model lanthanides.

    Methods

     The morphological and structural properties of the composites were studied through BET, FTIR, SEM, TEM, and XRD techniques. The adsorption process was modeled and optimized by methodology of response surface (RSM). Then, its four important models were validated by data fitting. Afterward, they were affirmed using ANOVA test.

    Results

     According to the outputs of the models, the reduced model was obtained as an appropriate model. Based on RSM plots, the adsorption rate at preliminary pH is low and gets better with increasing the pH value. At lower pH, there is a high concentration of H+ ion with smaller ionic radii and higher adsorption possibility, which makes it difficult to adsorb lanthanum ions by creating a competition between the excess of protons in the solution and cationic metal ions. This competitive adsorption and saturation of adsorptive sites on the surface of CS@nZVI sorbent with hydrogen ions together with repulsion forces are responsible for the La (III) less sorption. The optimum CS@nZVI removal efficiency of La (III) was 88% under the following conditions: pH = 8, 1.2 g/L CS@nZVI dosage, 5 mg/L initial La (III) concentration, and 180 min shaking time. Based on uptake kinetic models, the pseudo-second-order model is optimum in describing the rate equation of the adsorption process.

    Conclusions

     Successfully regeneration of CS@nZVI along with its good performance for Lanthanum separation provide a promising and feasible method in order to contaminated streams purification.

    Keywords: Chitosan, Adsorption, Optimization, Composite, Lanthanum}
  • Ahmadreza Yazdanbakhsh, Mohammad Rafiee, Masumeh Alimoradi*

    The goals of this study were to assess the microbiological quality and coastal water quality index (CWQI) in the Persian Gulf alongshore of Bandar Abbas city. Water samples were collected from five different coastal sites in spring and summer seasons. To assess the microbiological quality: Total Coliforms, Fecal Coliforms, Fecal Streptococci and Clostridium perfringens were measured. Also, eight physicochemical parameters (DO, BOD, TSS, Turbidity, Temperature, pH, Nitrate, Phosphate) were examined for calculating the CWQI. The mean for microbiological indicators was respectively, 3667, 1055, 50, 211 MPN/100ml. for physicochemical parameters, the average of water temperature was 32 °C, electrical conductivity was 57mmho/cm, the turbidity was 70.7 NTU, pH 8.1, and also the average concentration of phosphate, nitrate, nitrite, and ammonium was 180, 18.2, 4.9, 12.16μmol/L, and the mean of concentration BOD, COD and DO were 4.89, 11 and 6.8mg/L, respectively. In addition, the water quality index for all months and at selected stations was 65. The results showed that in the most samples the levels of microbiological indicators were exceeded the national standard and guideline values. Also, the computed CWQI showed that quality of water was weak. All the extracted results are closely related to the inlets connected to the sea. These inlets except the Ghadir station will affect the rest of the stations. In general, in low tide, the Bactria index was more than high tide

    Keywords: Microbiological Quality, Water Quality Index, Coastal Waters, Persian Gulf}
  • Ahmadreza Yazdanbakhsh, Kourosh Rahmani, Hasan Rahmani, Mansour Sarafraz, Masoumeh Tahmasebizadeh, Ayat Rahmani *
    Water samples of 0, 50, and 100 nephelometric turbidity units (NTU) spiked with fecal coliforms (107 CFU/ml) were exposed to natural sunshine in 1l quartz glass tubes fitted with rectors’ compound parabolic concentrators CPCS at two forms CPC1 (whit nanoparticle zinc oxide) and CPC2(without nanoparticle zinc oxide). The samples were characterized using the X-ray powder diffraction (XRD), scanning electron microscopy (SEM), and transmission electron microscope (TEM). On clear days, the complete inactivation times (more than 7-log unit reduction in bacterial population) in the systems with CPC1, and CPC2 were 15, and 30 min, respectively. The maximum temperatures obtained in the water samples were 80  for CPC1, and 82  for CPC2. The use of CPC1 with hydroxyl radicals (OH•) production significantly improved the efficiency of the old CPCS technique, since these systems (CPC1-2) shortened the exposure times to solar radiation and also minimized the negative effects of turbidity and also regrowth was zero in the disinfected samples. Due to two simultaneous effects of high temperatures and UV, regrowth in most ways of solar disinfection was not seen in these examples. Overall, this technology has been proved to be a good enhancement method to inactivate microorganisms under real conditions and represents a good alternative technique to drinking water treatment.
    Keywords: Compound parabolic concentrators (CPCs), Solar disinfection, Nano photocatalyst, Fecal coliforms}
  • احمدرضا یزدانبخش*، اکبر اسلامی، مهرنوش ابطحی، محمد داننده اسکویی
    زمینه و اهداف

    فاضلاب صنعت الکل سازی دارای آلودگی بسیار بالا و تصفیه آن مشکل می باشد. در این تحقیق کارایی فرایند ازن زنی در راکتور مارپیچ و تحت فشار و اختلاط بالا با استفاده از استاتیک میکسر و مقایسه کارایی آن با راکتور متداول ازن زنی به منظور تصفیه فاضلاب صنعت الکل سازی مورد بررسی قرار گرفته است.

    مواد و  روش ها

    این تحقیق بر روی پساب خروجی از واحد تصفیه بی هوازی فاضلاب واقعی حاصل از کارخانه الکل سازی در مقیاس آزمایشگاهی انجام شد. اکسیژن موردنیاز شیمیایی (COD)، اکسیژن موردنیاز بیوشیمیایی (BOD) و رنگ، آلاینده های مورد بررسی بودند.

    یافته ها

    نتایج حاصل از این مطالعه نشان داد که راکتور مارپیچی با اختلاط بالا در شرایط کاملا مشابه نسبت به راکتور متداول، کارایی بیشتری در حذف آلاینده ها و کاهش مصرف میزان ازن دارد. به طوری که در زمان ماند 30 دقیقه و pH برابر 3/5 راندمان حذف COD در راکتور مارپیچی با اختلاط بالا، 8/4 برابر راکتور متداول بود. بیشترین راندمان حذف برای شاخص COD در هر دو راکتور مارپیچی با اختلاط بالا و معمول در حداکثر زمان ماند فرایند در pH برابر 11 و برای رنگ در حداکثر زمان ماند فرایند در pH برابر 3/5 حاصل شد. همچنین نتایج نشان دهنده افزایش نسبت BOD/COD در هر دو راکتور در اثر فرایند ازن زنی بود.

    نتیجه گیری

    کارایی راکتور مارپیچی با اختلاط بالا با استفاده از استاتیک میکسر، نشانگر قابلیت کاربرد این راکتور برای تصفیه فاضلاب صنعت الکل سازی می باشد. همچنین می توان این راکتور را به عنوان پیش تصفیه و یا تصفیه پیشرفته فرایندهای بیولوژیکی جهت تصفیه بسیاری از فاضلاب های صنعتی مورد استفاده قرار داد.

    کلید واژگان: ازن, صنعت الکل سازی, راکتور تحت فشار و اختلاط بالا, رنگ, COD}
    Ahmadreza Yazdanbakhsh*, Akbar Eslami, Mehrnoosh Abtahi, Mohammad Danandeh oskouie
    Background and Aims

    Alcohol distillery wastewater is a highly polluted wastewater which its treatment poses a special problem. In this work, the efficiency of ozonation process exploited in a spiral high pressure super mixing reactor was studied for COD removal and decolorization of alcohol distilleries wastewater. The results was also compared with a conventional reactor.

    Materials and Methods

    The present laboratory-scale research was done on real effluent from anaerobic wastewater treatment unit of alcohol wastewater. Experiments were conducted in a pressurized spiral super mixing reactor equipped with static mixers and also in a control conventional reactor with the same volume. The process performance criteria, such as COD, BOD and color, were determined according to standards methods for water and wastewater examination.

    Results

    The pressurized spiral super mixing reactor showed high efficiency in removing pollutants and reducing ozone consumption as compared to conventional reactor. Typically, during 30 min, and pH =5.3, the COD removal efficiency in the pressurized spiral super mixing reactor was 4.8 times higher than that of conventional reactor. According to the results, the efficacy of ozonation process increased by changing the pH from acidic to alkaline. Generally, the respective highest removal efficiency of COD and color was obtained at pH=11 and pH=5.3 in both reactors at their maximum retention time. Also the biodegradability of wastewater (BOD/COD) was enhanced in both reactors following ozonation process.

    Conclusion

    The pressurized spiral super mixing reactor performance in reducing ozone consumption highlights the potential applicability of this reactor for wastewater treatment of alcohol industry. The reactor can be used as pre-treatment or post treatment processes for the appropriate treatment of industrial wastewater.

    Keywords: Ozone, Alcohol industry, Pressurized spiral super mixing reactor, Colour, COD}
  • مریم زارع بیدکی، احمدرضا یزدان بخش*، مهرنوش ابطحی محصل، مونا قاضی
    سابقه و هدف
    انتشار بیوآئروسل ها در طول فرآیندهای تصفیه فاضلاب به هوا یک مشکل عمده بهداشتی می باشد. در این مطالعه  اثر نوع سیستم هوادهی سطحی و عمقی بر تراکم و نوع باکتری ها و قارچ های هوابرد در دو تصفیه خانه فاضلاب مورد بررسی قرار گرفته است.
    مواد و روش ها
    این مطالعه توصیفی-مقطعی درتصفیه خانه های فاضلاب شهری در شهر تهران که به ترتیب دارای سیستم هوادهی سطحی و عمقی می باشند انجام شد. نمونه برداری برای تعیین تراکم و تشخیص بیوآئروسل ها با تناوب شش روز یک بار و در دو فصل تابستان و پاییز در سال 1396 انجام شد. علاوه برهوای اطراف واحد های هوادهی، هم چنین از واحدهای دانه گیر، ته نشینی ثانویه و دو نقطه کنترل نمونه ها برداشت شدند. تراکم باکتری ها و قارچ ها از طریق کشت و تشخیص گونه و جنس از طریق آزمون های استاندارد انجام گرفت.
    یافته ها
    نتایج نشان داد در تصفیه خانه با هوادهی سطحی بیش ترین انتشار بیو آئروسل ها در هر دو فصل از واحد های هوادهی صورت می گیرد. در این تصفیه خانه میانگین تراکم باکتری ها از این واحد به ترتیب در فصل تابستان و پائیز 6845 و 15784 CFU/m2/h و بیش ترین انتشار قارچ ها در فصل تابستان و پاییز به ترتیب  535CFU/m2/h  و899 CFU/m2/h اندازه گیری شد. انواعی از باکتری های گرم منفی، گرم مثبت و قارچ ها در هر دو تصفیه خانه شناسائی شدند.
    استنتاج
    بر اساس نتایج این مطالعه، خطرات ناشی از میزان انتشار بیوآئروسل ها در تصفیه خانه با سیستم هوادهی سطحی یا مکانیکی در مقایسه با هوادهی عمقی بیش تر است.
    کلید واژگان: بیوآئروسل, هوادهی سطحی, هوادهی عمقی, تصفیه خانه فاضلاب}
    Maryam Zare Bidaki, Ahmadreza Yazdanbakhsh*, Mehrnoosh Abtahi Mohasel, Mona Ghazi
    Background and purpose
    Emission of bioaerosols from wastewater treatment plants is a potential hazard to human health. In this study aimed at investigating the effects of surface and deep aeration techniques on density and type of airborne bacteria and fungi in two municipal wastewater treatment plants.
    Materials and methods
    This descriptive cross-sectional study was done in two wastewater treatment plants in Tehran equipped with surface and deep aerations. Microbial samples were taken from air beside aeration tank, grit chamber, secondary sedimentation basin and two control points (upwind and downwind) every 6 days during summer and autumn 2017. Samples were analyzed for density of bioaerosols and types of bacteria and fungus applying standard methods.
    Results
    Wastewater treatment plant with surface aeration tank had the greatest effect on emission of bioaerosols than the plant with deep aeration. Mean values for density of bacterial bioaerosols and fungal emission were 6845 and 15784 CFU/m2/h in summer and 535 and 899 CFU/m2/h in autumn, respectively. Different gram-positive and gram-negative bacteria were identified in both wastewater treatment plants investigated.
    Conclusion
    According to current study, emission of bioaerosol in wastewater treatment plants with surface aeration is more than that of those with deep aeration and has greater potential hazard.
    Keywords: bioaerosol, mechanical aeration, surface aeration, wastewater treatment plant}
  • Marziye Moradgholi, Mohamadreza Massoudinejad, Ehsan Aghayani, Ahmadreza Yazdanbakhsh *
    Background
    Although anaerobic system has been successfully used for treating the strong industrial wastewater, its efficiency for low-strength wastewater as municipal wastewater is not satisfying. This study aimed to enhance the capability of an anaerobic baffled reactor (ABR) for treating municipal wastewater.
    Methods
    A 7-L ABR with 5 compartments was operated for a 287-day period fed with primary effluent from a wastewater treatment plant at 17 to 19°C. The study was conducted in 2 phases. In the first phase, the performance of ABR and in the second phase, the performance of ESABR (ABR integrated with an electrochemical system) were investigated.
    Results
    The results of ABR operation indicated that at hydraulic retention time (HRT) =24 hours, the average removal efficiency of biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), total Kjeldahl nitrogen (TKN), total phosphorous (TP), and log reduction value (LRV) of coliforms were obtained to be 71%, 75%, 79%, 23%, 30.3%, and 5.8 Log, respectively. In this phase, when the HRT was decreased from 24 to 18 hours and from 18 to 14 hours, the removal efficiency of all parameters by the ABR was decreased. After the shift of ABR operation to ESABR, at HRT=24 hours and current density of 0.78 mA/cm2, the performance of the reactor was enhanced, so that the removal efficiency of BOD, COD, TSS, TKN, TP, and LRV of coliforms were achieved 16.8%, 15%, 4%, 10.7%, 49%, and 1 Log, which was greater than those obtained by ABR.
    Conclusion
    According to the results, this technology (SEABR) is suitable for treating the low-strength municipal wastewater.
    Keywords: Wastewater, Anaerobic baffled reactor, Electrical stimulated, Treatment}
  • احمد رضا یزدان بخش، محمد رفیعی، قاسم کیانی فیض آبادی*
    زمینه وهدف
    تکنولوژی آنوکسیک-اکسیک(A/O) ازروش های جدید تصفیه فاضلاب محسوب میگردد که در تصفیه خانه فاضلاب مهدیشهر مورد استفاده قرار گرفته است. با توجه به عدم انجام مطالعات کافی دراین زمینه، لزوم بررسی بیشتردرمورد عملکرد تصفیه خانه به روشA/O محسوس گردید. مطالعه حاضر با هدف ارزیابی عملکرد تصفیه خانه فاضلاب مهدیشهر انجام گرفت.
    موادوروش ها
    مطالعه توصیفی مقطعی حاضردر سال 2014 به مدت8 ماه انجام شد. درطول مدت مطالعه هرهفته دوباراز فاضلاب ورودی،حوض هوادهی وپساب خروجی نمونه برداری ودرمجموع200 نمونه فاضلاب برداشت گردید. کارآیی تصفیه خانه بوسیله پارامترهای BOD5،TSS و COD و نیزMLVSS ، MLSS و SVI درحوض هوادهی، طبق استاندارد متد بررسی گردید و داده ها با آنالیزهای آماری تجزیه و تحلیل شدند.
    یافته ها
    میانگین غلظت BOD5،TSS و CODورودی به ترتیب برابر6/221، 8/203 و321 میلیگرم برلیتر بود.میانگین غلظت آنها درپساب خروجی به ترتیب 65/23، 79/16 و 9/34 میلیگرم برلیتر محاسبه شد. براساس نتایج، میانگین راندمان حذف BOD5،TSS و CODبه ترتیب 25/87، 77/91 و29/87 درصد تعیین گردید که با استانداردهای پساب سازمان حفاظت محیط زیست ایران جهت مصارف کشاورزی مطابقت دارد. متوسط ماهیانه SVI ، 3/67 میلی لیتر درگرم بود ومیانگین MLSS و MLVSSبه ترتیب1880 و 1182 میلیگرم در لیترمشخص گردید.
    نتیجه گیری
    درمطالعه حاضر، کارایی فرایند A/O درحذف COD بطور متوسط حدود 89 درصد می باشد ونشان ازمیزان تجزیه پذیری بالای فاضلاب درراکتورA/O میباشد.همچنین نتایج نشان داد که فرایندA/O  دراین تصفیه خانه کارآمد بوده وپساب تولیدی از نظرپارامترهای مورد مطالعهBOD5) ،TSS وCOD ) با استانداردهای ایران مطابقت داشته ودارای قابلیت استفاده مجدد یا تخلیه به آبهای پذیرنده می باشد.
    کلید واژگان: آنوکسیک -اکسیک, لجن فعال, عملکرد, مهدیشهر}
    Ahmadreza Yazdanbakhsh, Mohammad Rafiee, Ghasem Kiani Feizabadi *
    Background
      Anoxic-oxic (A/O) is a new method of wastewater treatment and is being used in Mahdishahr wastewater plant. considering the lack of studies in this area, it seemed necessary to study the performance of A/O system in wastewater treatment. This study was carried out to evaluate the efficiency of Mahdishahr wastewater Treatment Plant.
    Materials and Methods
    The present cross sectional study was conducted in 2014 during 8 months. Sampling was performed two times per week from the incoming wastewater, aeration pond and effluent. Overall, 200 samples were collected. The efficiency of Treatment Plant was measured by TSS, BOD5, COD, MLSS, MLVSS, and SVI indices in aeration ponds based on standard method. Then the datas were analyzed by statistical analysis.
    Results
    The mean concentrations of BOD5, TSS and COD in influent were 221.6 mg/l, 203.8mg/l and 321 mg/l respectively. The mean concentrations of BOD5, TSS and COD in effluent were 23.65 mg/l, 16.79 mg/l and 34.9 mg/l respectively. According to the results the average removal efficiency of BOD5, TSS and COD were about 87.25%, 91.77% and 87.29% respectively. These results are in accordance with standards of Iranian Department of Environment to be used for agricultural purposes. During the study, the monthly mean for SVI was 67.3 ml/g and the mean for MLSS and MLVSS was 1880 and 1182 mg/l respectively.
    Conclusion
      in present study, the efficiency of A/O process in COD removals is approximately 89 percent, representing high degradability of wastewater in A/O reactor. In addition, according to the results this method was efficient and the effluent complied with Iranian standards in terms of COD, TSS and BOD5, thus the flow is suitable for reuse or discharge to water courses.
    Keywords: Anoxic-oxic, Activated sludge, Performance, Mahdishahr}
  • مریم امینی، احمدرضا یزدانبخش، اکبر اسلامی، احسان آقایانی
    زمینه و اهداف
    صنعت نساجی یکی از بزرگترین مصرف کنندگان آب در جهان است که فاضلاب آن با مقادیر زیاد رنگ، اکسیژن مورد نیاز شیمیایی بالا، pH با نوسان زیاد و درجه حرارت بالا شناخته شده است. در میان روش های تصفیه فاضلاب صنایع نساجی، فرایند انعقاد به دلیل راهبری ساده و اثربخش و همچنین هزینه سرمایه گذاری نسبتا پایین به طور گسترده ای مورد استفاده قرار می گیرد.
    مواد و روش ها
    مطالعه در مقیاس آزمایشگاهی بر روی نمونه واقعی و با استفاده از سه منعقد کننده معدنی پلی آلومینیم کلراید، سولفات فریک و کلرورفریک با استفاده از دستگاه جارتست انجام شد. به منظور بهینه سازی فرآیند، متغیرهای pH، غلظت ماده منعفد کننده، زمان و سرعت انعقاد در حذف رنگ و COD مورد بررسی قرار گرفت. تعیین نسبت BOD5/ COD به عنوان شاخص تجزیه پذیری استفاده شد.
    یافته ها
    در شرایط بهینه فرآیند (pH برابر با 9، دوز 250 میلی گرم بر لیتر و سرعت انعقاد 175 دور در دقیقه با زمان 5 دقیقه)، بیشترین مقادیر راندمان حذف رنگ و اکسیژن مورد نیاز شیمیایی با کاربرد پلی آلومینیوم کلراید به ترتیب 95 و 77/4 درصد حاصل شد. کاربرد منعقد کننده پلی آلومینیوم کلراید در شرایط بهینه میزان تجزیه پذیری فاضلاب را از 0/07 به 0/21 افزایش داد.
    نتیجه گیری
    اگرچه فرآیند انعقاد، درصد بالایی از بار آلودگی موجود در فاضلاب را کاهش ودرصد تجزیه پذیری را افزایش می دهد، اما تصفیه بیشتر پساب برای تخلیه به محیط زیست ضروری می باشد.
    کلید واژگان: فاضلاب نساجی, رنگ زا, انعقاد, تجزیه پذیری بیولوژیکی}
    Maryam Amini, Ahmadreza Yazdanbakhsh, Akbar Eslami, Ehsan Aghayani
    Background And Aim
    Textile industry is one of the largest consumers of water in the world. The wastewater from the textile industry is known to have strong colour, chemical oxygen demand (COD), highly fluctuating pH and high temperature. The release of coloured wastewater represents a serious environmental and public health concern. Among the various physicochemical and biological methods of textile wastewater treatment, coagulationflocculation is considered as an attractive and favourable technique because of its low cost, easy operation and high efficiency.
    Materials And Methods
    The study was conducted in the laboratory scale using Jar test. Dye removal from real wastewater was investigated by the use of three mineral coagulants including poly aluminum chloride, ferric sulfate and ferric chloride. In order to optimize the process, parameters including pH, coagulant dose, time and speed of coagulation were considered. Treated samples were analysed to determine the residual color and COD.
    Results
    According to the results of our experiments, under optimum conditions of process (pH 9, doses of 250 mg/lcoagulant and coagulation speed of 175 rpm with a duration of 5 minutes), the highest removal efficiencies (COD 44.4% and color 95%) were obtained by the use of poly aluminum chloride. The results showed that poly aluminum chloride enhanced the biodegradability of wastewater from 0.07 to 0.21 at optimized process conditions.
    Conclusion
    Although the coagulation process reduced a large percentage of pollution load in the wastewater, another process has to be followed to meet the wastewater discharge standards in receiving sources.
    Keywords: Textile wastewater, Dye, Coagulation, Biodegradability}
  • Ahmad Reza Yazdanbakhsh, Mohammad Hasan Abasi, Zeinab Gholami, Moayed Avazpour*
    Background
    The presence of heavy metals in water resources above threshold levels can be toxic and carcinogenic for consumers. This study determined the concentrations of heavy metals in the drinking water distribution network and resources of the city of Ilam in Iran.
    Methods
    In this cross-sectional study from 6 sources of water supply and also, different parts of the water supply system of Ilam city, samples were collected based on standard sampling methods. The samples were tested with a BRAIC atomic absorption spectrophotometer. The data was analyzed using nonparametric Mann-Whitney test.
    Results
    The concentration of zinc in all water sources of the city of Ilam was higher than WHO guidelines and Iranian standard 1053. Contamination by cobalt, arsenic and lead from Ilam dam, Pich-e Ashoori well and Haft Cheshmeh well was higher than national and international standards. The amount of cobalt and mercury at Ilam dam was significantly different from the levels at other sources (P
    Conclusion
    The use of pesticides in the agricultural sector, contamination of water by human waste and aged and worn water pipes are the likely sources of the increased concentrations of heavy metals, especially lead and arsenic. Because there is a cumulative effect from these metals, appropriate measures are necessary by the relevant agencies to address this problem.
    Keywords: Water resources, Distribution network, Heavy metals, Ilam}
  • احمدرضا یزدانبخش، عمران شعبان زاده سراجی، سیما الیاسی، اسماعیل جوادی
    اهداف و
    زمینه
    ترکیبات فنولیک موجود در آب دارای اثرات زیان آور برای سلامتی و محیط زیست بوده و مزه ناخوشایندی در آب آشامیدنی ایجاد میکند، به همین جهت جاذب های متعددی برای حذف فنول از آب پیشنهاد شده است. هدف این مطالعه بررسی کارایی باگاس نیشکر جهت حذف فنول از محلولهای آبی میباشد
    مواد و روش ها
    باگاس تهیه شده پس از آماده سازی و اضافه نمودن مقادیر مشخص فنول، در بازه های زمانی معین توسط سانتریفیوژ از محلول جدا شده و میزان جذب محلول باقیمانده توسط دستگاه اسپکتروفتومتر خوانده شد. تحلیل داده ها بوسیله نرم افزارهای EXCEL2010 و PRISM6 صورت گرفت. موازین اخلاقی مربوط به روش کار و استفاده از منابع رعایت گردید
    یافته ها
    با افزایش pH وغلظت اولیه فنول راندمان جذب کاهش یافت. همچنین با افزایش مقدار جاذب و مدت زمان تماس راندمان جذب افزایش یافت. شرایط بهینه برای حذف فنل pH برابر 3، غلظت باگاس 2 g/L و زمان 50 دقیقه و ظرفیت جذب توسط باگاس برابر16 mg/g بدست آمد. آنالیز داده های تجربی با مدلهای جذب فرندلیچ و لانگمویر به ترتیب دارای ضریب همبستگی 0.9755و 0.8359میباشد
    نتیجه گیری
    نتایج این مطالعه نشان داد با فراهم نمودن شرایط بهینه، میتوان از باگاس بعنوان یک جاذب آلی برای حذف مناسب فنول استفاده نمود. بنابراین با توجه به اینکه ضایعات باگاس در مقادیر زیادی در فراوری تهیه شکر تولید میشود، میتوان از آن به عنوان یک جاذب ارزان قیمت استفاده نمود.
    کلید واژگان: باگاس نیشکر, جذب سطحی, فنول, محلول آبی}
    Ahmad Reza Yazdanbakhsh, Omran Shabanzadeh Seraji, Sima Elyasi, Ismael Javadi
    Background And Aims
    Phenolic compounds in water and wastewater not only have deleterious effects on human health and ecosystem, but also change water flavor. Various adsorbents have therefore been suggested for phenol removal from water. In this article, the adsorptive removal of phenol from aqueous solutions by sugar bagasse was investigated.
    Material and
    Methods
    Prepared bagasse was activated and certain amount of phenol was added on it, tubes were centrifuged in certain time intervals, then the bagasse removed from solution. Following adsorbent, the solution was centrifuged and the prepared bagasse were separated from the solution at certain time intervals.
    Residual solution was analyzed with UV spectrophotometer for remaining phenol concentrations. Data were analyzed using EXCEL2010 and PRISM6 software. All ethical issues have been considered throughout the study.
    Results
    The results showed that phenol adsorption by the sugar bagasse decreased with increase in pH and initial phenol concentration, while it was decreased with increase in adsorbent dose, contact time, and temperature. In 10 and 20 mg/L of phenol concentration, a high removal efficiency (≥ 50 %) was observed.
    The optimal condition adsorption of phenol were suitable pH=3, adsorbent dosage=2 g and contact = 50 min. The maximum adsorption capacity was also 16mg/g. Experimental data were analyzed with Freundlich and Langmuir isotherm models and the correlation coefficients were 0.9755 and 0.8359, respectively.
    Conclusion
    Bagasse, as a new adsorbent, could effectively remove phenol in optimal conditions. The adsorption isotherm was best fitted by Freundlich adsorption model.
    Keywords: Bagasse, Adsorption, Phenol, Aqueous solution}
  • علی اوغازیان، احمدرضا یزدانبخش، اکبر اسلامی، انور اسدی
    زمینه و اهداف
    ایبوپروفن یکی از پرمصرف ترین داروهای ضدالتهابی غیراستروئیدی است و جهت کاهش دردهای اسکلتی عضلانی و ضد درد در طیف گسترده ای استفاده می شود. این مطالعه با هدف بررسی کارآیی فرآیند ازن زنی جهت حذف ایبوپروفن در راکتور نیمه پیوسته با جریان قالبی از محلول های آبی انجام گرفت.
    مواد و روش ها
    در این مطالعه از یک راکتور ازن زنی با جریان نیمه پیوسته قالبی در مقیاس آزمایشگاهی استفاده شد. چهار متغیر، pH، دوز ازن، زمان ماند هیدرولیکی و غلظت اولیه ایبوپروفن که ممکن است بر روی میزان تخریب ایبوپروفن تاثیرگذار باشند، مورد بررسی قرار گرفت. آنالیز نمونه ها برای اندازه گیری ایبوپروفن با استفاده از دستگاه HPLC صورت گرفت. در انجام این طرح و استفاده از منابع، رعایت موازین اخلاقی انجام شد.
    یافته ها
    تحت شرایط بهینه 8=pH، زمان ماند هیدرولیکی 60 دقیقه، غلظت اولیه ایبوپروفن 5 میلی گرم در لیتر و غلظت ازن تزریقی 5/2 گرم در ساعت) میزان حذف 59% بدست آمد. همچنین نشان داده شد، حذف ایبوپروفن از سینتیک درجه اول پیروی می کند.
    نتیجه گیری
    متغیرهای عملیاتی pH، غلظت ازن تزریقی، زمان ماند هیدرولیکی و غلظت اولیه ایبوروفن با استفاده از جریان قالبی به منظور بهبود تماس بین ازن و دارو، بهینه سازی شد.pH و زمان ماند هیدرولیکی مهم ترین متغیرهای تاثیرگذار در حذف ایبوپروفن بودند. همچنین مدل پیش بینی به دست آمد که به ما امکان پیش بینی کارآیی تخریب ایبوپروفن را به عنوان تابعی از pH و HRT تحت شرایط آزمایشگاهی تست شده را می دهد.
    کلید واژگان: داروهای ضد التهابی غیر استروئیدی, ایبوپروفن, ازن زنی, زمان ماند هیدرولیکی}
    Ali Oghazyan, Ahmadreza Yazdanbakhsh, Akbar Eslami, Anvar Asadi
    Background And Aims
    Ibuprofen (IBU) is one of the most consumed nonsteroidal anti-inflammatory drugs (NSAIDs) widely used in musculoskeletal and analgesic treatments. This study set out with the aim of assessing the efficiency of conventional ozonation process in a semi-batch plug-flow reactor in order to remove IBU from aqueous solutions.
    Materials And Methods
    A laboratory scale semi-batch plug-flow ozonation reactor was employed during the present study. Four variables including pH, dosage of ozone, hydraulic retention time (HRT), and initial Ibuprofen concentration, which might affect the degradation of Ibuprofen, were taken into consideration. The IBU concentration was determined using HPLC.
    Results
    Working under optimal operating conditions (pH = 8, HRT = 60 min, C=5 mg/L and Ozone dose 2/5 g/h), about 59% IBU degradation was noticed. Results also revealed that the degradation of IBU well fitted with the firstorder kinetics.
    Conclusion
    The operating variables of pH, dosage of ozone, initial Ibuprofen concentration, and HRT were optimized using a plug-flow reactor to improve contact between dissolved ozone and the drug. pH and HRT were the most affecting variables. Furthermore, a predictive model allowing us to predict the percentage of IBP degradation
    as a function of pH and HRT under experimental conditions was obtained.
    Keywords: Non, steroidal anti, inflammatory drugs, Ibuprofen, Ozonation, Hydraulic retention time}
  • احمد رضا یزدان بخش، حسین حاتمی، غلامعلی شریفی عرب*، مجید عرب عامری
    مقدمه
    با توجه به شرایط آب و هوایی ایران، شتر می تواند به عنوان منبع پروتئینی ارزشمندی در آب و هوای کویری در نظر گرفته شود. آلودگی های انگلی از شایع ترین امراض دامی بوده که علاوه بر زیان ها و مخاطرات بهداشتی، خسارات اقتصادی فراوانی را به دنبال دارد. اجرای این پروژه با هدف شناسایی انگل های شایع در کبد شتر صورت گرفته تا با کمک به اجرای برنامه مبارزه علیه بیماری های انگلی بتوان اقدام موثری در کاهش این گونه بیماری ها نمود.
    مواد و روش ها
    این پروژه از فروردین سال 94 تا پایان مهرماه 94 صورت گرفته است، جهت تخمین میزان آلودگی انگلی کبدهای شتر، تعداد 94 نمونه از کبد شترهای کشتار شده در کشتارگاه شاهرود گرفته و نمونه ها پس از برش و خرد کردن به صورت قطعات دو تا سه سانتی متری جمع آوری و پس از شناورسازی و الک کردن، میزان آلودگی آن محاسبه گردید.
    نتایج
    شایع ترین علت ضبط کبد در تعداد 94 نفر شتر کشتار شده، کیست هیداتیک می باشد که با 45/7 درصد بیشترین آلودگی را به خود اختصاص داده است. در رتبه بعدی، فاسیولا با فراوانی 06/1 درصد قرار داشت اما هیچ گونه آلودگی انگلی دیکروسلیوم مشاهده نگردید. ضمنا باتوجه به بررسی صورت گرفته، صددرصد شترانی که به کیست کبدی آلوده بودند دارای آلودگی انگلی ریوی نیز بودند.
    نتیجه گیری
    این مطالعه نشان می دهد که شیوع آلودگی کبدهای شتر کشتار شده در شاهرود به انگل های فوق قابل توجه می باشد که این مساله علاوه بر تحمیل زیان های اقتصادی ناشی از ضبط اندام آلوده، نشان دهنده وجود زمینه خطرات بهداشتی برای مصرف کنندگان منطقه می باشد. لذا با توجه به چرخه زندگی و انتقال این انگل ها، به کارگیری روش های پیشگیری بیماری با کمک سازمان دامپزشکی و اقدامات بهداشتی و کنترلی مناسب را طلب می نماید. همچنین با توجه به مخاطرات بهداشتی آلودگی انگلی و آلودگی قابل توجه شترها به انگل های بررسی شده، به کارگیری روش های پیشگیری بیماری با کمک شترداران و سازمان دامپزشکی ضروری می باشد.
    کلید واژگان: شتر, کیست هیداتیک, آلودگی انگلی, شاهرود}
    Ahmadreza Yazdanbakhsh, Hossein Hatami, Gholamali Sharifiarab, Majid Arabameri
    Introduction
    Considering conditions of Iran climatic, camel meat can be a valuable protein source in desert climate. A parasitic contamination is the most common diseases in livestock which causes economical losses in addition to health risks. The aim of the study was to identify the most common parasites in the camel liver in order to fight against parasitic diseases and reduced them effectivly.
    Methods
    The project was conducted from March 2015 until October 2015. Ninety-four liver samples were taken from Shahroud slaughterhouse to estimate the level of parasitic infections. Sampls were chopping into 2-3 cm pieces and the amount of contamination was measured after floating and sifting.
    Results
    The most common causes of liver infection in slaughtered camels were hydatid cyst with percentage of 7.45 and fasciola with 1.06 %, but there is no dicrocoelium infection. Meanwhile, results of this survey revealed that all camels with infected liver had also lung infection.
    Conclusion
    This study showed that the rate of liver infection in Shahroud slaughtered camels was considerably high. This indicates health risks for consumers in addition to economic losses. Considering the life cycle of these parasites, prevention of diseases by veterinary organization and adequate health and control evaluation are necessary. Due to health risks and considerable camel infections, disease prevention methods should be done in cooperation with livestock drivers and veterinary organization.
    Keywords: Camel, Hydatidosis, liver, Parasites infected, Shahroud}
  • احمد رضا یزدان بخش، انوشیروان محسنی بندپی، ابوطالب بای*، مهدی صادقی
    زمینه و هدف
    استخرهای شنا و جکوزی ها از جمله مراکز ورزشی و تفریحی هستند که افراد زیادی در سنین و قشرهای گوناگون از آن استفاده می کنند.با توجه به اهمیت حفظ بهداشت و سلامتی شناگران، مطالعه حاضر با هدف بررسی ارتباط بین مشخصه های فیزیکوشیمیایی و آلودگی میکروبی در آب جکوزی واستخرهای شنا در استان گلستان انجام شد.
    روش کار
    در این مطالعه مقطعی با رویکرد توصیفی - تحلیلی، جامعه مورد مطالعه شامل 8استخر فعال سرپوشیده دارای جکوزی در سطح استان گلستان بود. بررسی پارامترهای میکروبی(کلکلیفرم،اشرشیاکلی،استرپتوکوک مدفوعی و سودوموناس) و فیزیکوشیمیایی(دما،pH، کدورت، کلر باقی مانده آزاد)بر اساس استاندارد متد انجام شد. تجزیه و تحلیل داده هابا استفاده از نرم افزار آماریSPSS(نسخه 18) و آزمون های کروسکال والیس، ضریب همبستگی اسپیرمن و شاخهای مرکزی انجام شد.
    یافته ها
    با توجه به نتایج مطالعه، دراستخرهای شنا بین کدورت و سودوموناس همبستگی مثبت و معنی داری وجود داشت( p=0/017)،اما بین کدورت و سایر میکروارگانیسم ها ارتباطی مشاهده نشد(P<0/05).در جکوزی ها بین کل کلیفرم ها(0/002=p) و استرپتوکوک های مدفوعی(0/035=p) همبستگی مثبت و معنی داری مشاهده شد.بین میزان کلر آزاد باقی مانده و ارگانیسم های شاخص دراستخرها وجکوزی هاارتباط عکس وجود داشت؛ به طوریکه هرچه میزان کل باقی مانده بیشتر بود، تعداد این میکروارگانیسم ها کمتر بود.
    نتیجه گیری
    پراکندگی زیادی در آلودگی میکروبیاستخرها و جکوزی ها و همچنین متغیرهای فیزیکوشیمیایی وجود دارد. به عبارت دیگراستخرها و جکوزی ها در برخی روزها بسیار تمیز و در برخی روزها دارای آلودگی بسیار زیاد از نظر وجود این میکروارگانیسم ها، کدورت و میزان کلر باقی مانده هستند؛که این نشان دهنده عدم راهبری مناسباستخرها و جکوزی ها به تناسب تعداد شناگران و میزان گندزدایی می باشد.
    کلید واژگان: آلودگی میکروبی, جکوزی, استخر شنا, کدورت, کلر آزاد باقی مانده}
    Ahmad Reza Yazdanbakhsh, Anoushiravan Mohseni Bandpei, Abotaleb Bay*, Mahdi Sadeghi
    Background And Aims
    Swimming pools and Jacuzzis as sports and recreational centers are used by many people in different ages and classes. The aim of this study was to investigate the relationship between physicochemical characteristics and microbial contamination in Jacuzzi water and swimming pools in Golestan province.
    Materials And Methods
    In the present cross-sectional study with descriptive-analytic approach, eight indoor swimming pool and Jacuzzi were chosen to be investigated in the Golestan province. Biological (Total coliform, E.coli, Streptococcus, Pseudomonas) and physiochemical parameters (temperature, pH, turbidity, free chlorine residual) were performed according to standard methods.
    Results
    The obtained results showed a significant and positive correlation between turbidity and Pseudomonas in swimming pools (p=0.017). However, no significant relationship was observed between turbidity and other microorganisms. Also, it was revealed that there was a significant and positive correlation between total coliforms and fecal streptococci in the Jacuzzis . Beside an inverse relationship was found btween the free residual chlorine and indicator organisms.
    Conclusions
    There is a high dispersion between microbial contamination and physicochemical variables in pools and Jacuzzis. In other wordæ pools and Jacuzzis are very clean on some days and on some others, they are too polluted from the aspect of microorganisms’ presence and turbidity.. This indicates that there is no appropriate operation for pools and Jacuzzis in proportion of swimmer numbers and disinfection rate.
    Keywords: Microbial Pollution, Jacuzzi, swimming pool, Turbidity, Free residual chlorine}
  • مصطفی قارلقی، احمد رضا یزدانبخش، اکبر اسلامی، احسان آقایانی
    سابقه و هدف
    یکی از منابع عظیم آبی قابل استفاده، پساب تصفیه خانه فاضلاب شهری است. استفاده مجدد از این پسآب نیازمند استانداردهایی فراتر از استانداردهای ثانویه می باشد و نیاز است تا آلاینده های آلی و بعضی از ترکیبات مانند نیترات و فسفات موجود در پسآب به میزان بیشتری حذف گردند. در این تحقیق حذف این ترکیبات از پساب ثانویه با استفاده از جاذب نانو ذرات اکسید آهن (مگنتیت) مورد بررسی قرار گرفته است.
    مواد و روش ها
    پژوهش حاضر در سیستم آزمایشگاهی و روی پسآب واقعی یکی از تصفیه خانه های فاضلاب شهری انجام گرفت و نانو ذرات اکسید آهن برای حذف آلاینده های مورد نظر استفاده شد و اثر pH، زمان تماس و غلظت جاذب روی حذف این آلاینده ها به روش بهینه سازی عامل در واحد زمان مورد بررسی قرار گرفت. سپس ایزوترم و کینتیک جذب در شرایط بهینه متغیرها تعیین گردید.
    یافته ها
    میانگین ( Biochemical oxygen demand (BOD5، chemical oxygen demand (COD)، نیترات و فسفات در پسآب تصفیه خانه به ترتیب برابر با 25، 43، 63 و 6/8 میلی گرم بر لیتر اندازه گیری شد. شرایط بهینه برای جذب این آلاینده ها توسط جاذب نانو ذرات اکسید آهن در pH برابر 3، زمان تماس 15 دقیقه و دوز جاذب g/l1 به دست آمد. در شرایط بهینه میزان حذف فسفات، نیترات، BOD5 وCOD به ترتیب 54، 5/11، 56 و 75 درصد و ظرفیت جذب به ترتیب (mg/g) 7/4، 6/1، 14و32 به دست آمد. نتایج نشان داد جذب توسط Fe3O4از مدل فروندلیج و کینتیک درجه اول برای COD و فسفات و برای BOD5 و نیترات از کینتیک درجه دوم پیروی می کند.
    استنتاج: نانوذرات اکسید آهن پتانسیل نسبتا مناسبی برای حذف فسفر، BOD5 وCOD از پساب تصفیه ثانویه دارد ولی جهت حذف نیترات کارائی مناسب ندارد.
    کلید واژگان: Fe3O4MNPs, تر کیبات آلی (COD, BOD5), NO, 3و PO43, تصفیه پیشرفته پساب}
    Mostafa Gharloghi, Ahmadreza Yazdanbakhsh, Akbar Eslami, Ehsan Aghayani
    Background and
    Purpose
    Municipal wastewater treatment plant effluents are amongst the main available water sources. Reuse of these effluents requires further standards beyond secondary standards. Therefore, removal of organic pollutants and some compounds such as nitrate and phosphate from effluents should be done at a greater extent. In this study, removal of these compounds from secondary effluent was examined using an absorbent of iron oxide nanoparticles (MNPs Fe3O4).
    Materials And Methods
    The research was carried out using actual effluent of urban wastewater treatment plant in laboratory scale. The iron oxide nanoparticles (MNPs Fe3O4) was used for removal of target pollutants by investigating different parameters such as pH, initial concentration, contact time, and adsorbent dosage using optimization of one factor at a time. Afterwards, the optimum condition was determined by adsorption and kinetic isotherms.
    Results
    The average BOD5, COD, nitrogen, and phosphorus in wastewater treatment plant effluent were found to be 25, 43, 63 and 8.6 mg /L, respectively. The optimum conditions for adsorption of these pollutants by Fe3O4MNPs were obtained at pH 3, 15 min contact time and absorbent dosage of 1 g/l. Removal of PO43-, NO-3, BOD5 and COD in the optimum condition was obtained to be 54, 11.5, 56, and 75%, respectively, and the maximum adsorption capacities for target pollutants were 4.7, 1.6, 14, and 32 mg/g. The results showed the adsorption by Fe3O4 followed the Freundlich model and pseudo first-order kinetic for COD and PO43- and pseudo second-order kinetic for BOD5 and NO-3 removal.
    Conclusion
    Iron oxide nanoparticles (MNPs Fe3O4) is suitable for removal of some pollutants (COD, BOD5 and PO43-) from the secondary effluent, but this absorbent is not effective for nitrate removal.
    Keywords: Fe3O4MNPs, organic compound, COD, BOD5, nitrate, phosphate, advanced treatment, effluent}
  • احمدرضا یزدانبخش، علی اکبر رودباری، سعید ناظمی*، مهدی میرزایی، فاطمه داوردوست، پیراسته نوروزی، مژگان فضلی
    مقدمه
    از آنجایی که اعضاء تیم دندانپزشکی و بیماران در معرض آب و آئروسل های ایجاد شده از یونیت دندانپزشکی قرار می گیرند، بررسی کیفیت آب یونیت دندانپزشکی از اهمیت قابل توجهی برخوردار می باشد. هدف از این مطالعه بررسی میزان آلودگی باکتریایی سیستم های آبی یونیت های کلینیک های دندانپزشکی شاهرود بود.
    مواد و روش ها
    این مطالعه توصیفی- تحلیلی به روش سرشماری در سال 1393 بر روی آب یونیت کلیه مطب ها و کلینیک های دندانپزشکی شهر شاهرود انجام شد، 560 نمونه آب از 4 قسمت یونیت شامل پوار آب و هوا، مجرای سرتوربین قبل و بعد از فلاشینگ، لیوان پر کن و 2 نمونه آب از منبع آب شهری ورودی به یونیت ها گرفته شد. نمونه گیری در روز شنبه و پنج شنبه قبل از شروع کار و بعد از اتمام کار صورت گرفت. نمونه گیری با استفاده از ظروف استریل صورت گرفته و به آزمایشگاه میکروبیولوژی منتقل شد. تمام نمونه ها در محیط بلادآگار و مک کانکی آگار به مدت 72 ساعت در دمای C°37 انکوبه شدند، سپس کلنی های رشدیافته شمارش شدند. ضمنا تمامی نمونه ها در محیط کشت اختصاص یل ژیونلا) BCYE حاوی آنتی بیوتیک های پلیمیکسین B و نکومایسینوسیکلوهگزامید) درجار شمعدار در 37 درجه سانتی گراد و رطوبت 70-90 درصد انکوبه شدند. داده ها با استفاده از نرم افزار SPSS و آزمون آماری ANOVA و آزمون t مستقل مورد تجزیه و تحلیل آماری قرار گرفت و میزان 05/0P< معنی دار تلقی گردید.
    نتایج
    کلیه نمونه ها از نظر وجود باکتری لژیونلا منفی بودند. میانگین شمارش باکتری ها cfu/ml4671 بود میانگین شمارش باکتری ها روز چهارشنبه (cfu/ml3860) کمتر از آلودگی در روز شنبه (میانگین cfu/ml6320) بود اما براساس آزمون آماری) t142/0P=) اختلاف بین نتایج معنی دار نبود، همچنین میانگین شمارش باکتریایی به تفکیک زمان نمونه گیری، میزان آلودگی بعد از کار (cfu/ml6250) بیشتر از قبل از شروع کار (cfu/ml4050) بود (186/0P=). بیشترین میانگین شمارش باکتری ها مربوط به مطب های بخش خصوصی و کمترین میانگین مربوط به درمانگاه خیریه بود (01/0P<).
    نتیجه گیری
    نتایج این مطالعه نشان داد که میزان آلودگی آب یونیت های دندان پزشکی بالا می باشد و دندانپزشکان باید همواره به کنترل میکروبی آب یونیت های دندانپزشکی توجه داشته باشند تا به ارتقاء سلامت خود، بیماران و پرسنل مطب کمک نمایند.
    کلید واژگان: شاهرود, بیوفیلم, آب یونیت دندانپزشکی}
    Ahmadreza Yazdanbakhsh, Ali Akbar Roudbari, Saeid Nazemi, Mehdi Mirzai, Fatemeh Davardoost, Pirasteh Norozi, Moghgan Fazli
    Introduction
    Assessment of microbial contamination in dental unit waterlines has been focused on because of high risk of dangerous infections in immunocompromised patients. The purpose of this study was to evaluate the bacterial contamination of water supply in dental unit water lines at Shahroud dental offices.
    Methods
    In this descriptive analytical study we investigated 560 water samples collected from four parts of each unit including air/water syringe, turbine hand piece (before &after flushing), cup filler and 2 water sample collected from city water reservoir in Shahroud dental office during 2015. Water samples were taken on Saturdays (the first working day in a week) and Thursday (the last working day in a week), before and after treatment on the same units.Samples were transported in closed sterile containers to microbiology laboratory. All samples were incubated on blood agar and McCaskey plates for 72 hours at 37°C. Bacterial contamination was then evaluated. All samples were analyzed for legionella. Data were analyzed by ANOVA and t-test.
    Results
    Total mean bacterial count was 4671 cfu/ml. Mean bacterial contamination on Saturdays (6320 cfu/ml) were higher than Thursdays (3860 cfu/ml). Mean bacterial contamination before treatment was (4050 cfu/ml) less than the end of treatment (6250 cfu/ml) on the same unit. Mean bacterial contaminations of self-Dental Office was higher than other clinics
    Conclusion
    The result of this study demonstrated that microbiological level of dental unit waterlines is high. The dentists must be aware of the high level of microorganisms in the dental unit’s water and thus minimize the risk of infection in both staff and patients.
    Keywords: Shahroud, Biofilm, Dental unit water}
  • Yosef Taher, Ghasemi, Iraj Nikokar*, Ahmad Reza Yazdanbakhsh, Hadi Sedigh Ebrahim, Saraie, Robabe Vakili Sadeghi, Abdolhalim Rajabi
    Background
    Certain social determinants may influence host susceptibility to tuberculosis (TB) infections, and increase the risk of developing the disease.
    Objectives
    The present study aimed to evaluate the effects of several host and environmental factors on the risk of TB in northern Iranian households.Patients and
    Methods
    This case-control study was conducted for one year between 2010 and 2011 in the Guilan province in Iran. Eighty-seven confirmed TB positive cases, based on convenience sampling, were included in this study. A patient positive for TB was confirmed by a positive sputum smear, chest X-ray, and clinical manifestations as diagnosed by a physician. The data were collected using observational methods, and were analyzed by SPSS software.
    Results
    The average mean age of the TB cases was 51 ± 22 years old, and 40.2% (35/87) of the TB cases were male and 59.8% (52/87) were female. The majority of TB cases were from rural areas (71.3%, 62/87), while 28.7% (25/87) were from urban areas. Significant differences (P < 0.001) were observed between the geographical conditions and distribution of the disease. The room density of the individuals was significantly different (2.9 ± 1.2 vs. 2.2 ± 1.9, P < 0.002) among the TB cases and control group, respectively. A statistical difference was observed between the groups in terms of the building materials (P < 0.05), while significantly inadequate UV irradiation was seen in the houses of the TB patients, compared to the control group (82.8% vs. 14.9%, P < 0.001). The hygiene of the houses seemed to be a significant risk factor (P < 0.001) for TB infection.
    Conclusions
    The results suggest that in the studied region several host and environmental factors were associated with higher risks of TB infection.
    Keywords: Tuberculosis, Risk Factors, Social Medicine, Case, Control Studies}
  • Ahmad Reza Yazdanbakhsh, Hasti Daraei*, Masomeh Davoodabadi
    Phenol is one of the serious pollutants from the chemical and petrochemical industries. This pollutant due to its convoluted structure is resistant to biodegradation. One of the methods that are useful to remove this pollutant is advanced oxidation (AOP).A laboratory scale study was done on a synthetic wastewater containing phenol. All experiments were done in batch conditions and effect of variables pH, amount of hydrogen peroxide, iron dosage, contact time and an initial concentration on the phenol removal were tested. The remaining phenol concentration was evaluated using the DR-5000 device. In order to effect of these parameters, the experiment was performance at pH 2 to 6, 5 to 45 ml/ml of peroxide, and time of 5 to 60 minutes with 2 to 15 g/ml iron (Fe˚).The optimum pH, the ratio of hydrogen, Fe˚and time were 3, 15 ml, 8g and 5 minutes respectively. Chemical oxygen demand (COD) index was chosen as the parameter for evaluation in this study. Result showed that mineralization of phenol was not complete. The COD removal efficiency was obtained 71%.According to the results of this study, Fenton-like process can be used for conversion organic resistant compounds to other compounds with lower toxicity.
    Keywords: Fenton, like, Advance Oxidation, Phenol, Iron Powder}
  • احمدرضا یزدانبخش، محمدرضا مسعودی نژاد، ستار محمدی*
    زمینه و هدف
    درمیان مواد هیومیکی موجود در آب، اسید هیومیک بعنوان مهمترین ترکیب پیش ساز تشکیل محصولات جانبی ناشی از کلرزنی مطرح است. حذف اسید هیومیک، کاهش تولید ترکیبات جانبی ناشی از کلرزنی آب را بدنبال دارد. این مطالعه با هدف بررسی کارآیی UV، O3 و UV/O3 در راکتور با جریان قالبی جهت حذف اسید هیومیک از آب انجام گرفت.
    مواد و روش ها
    این مطالعه در سه مرحله برروی نمونه های سنتتیک آب حاوی غلظت های مشخص از اسید هیومیک در یک سیستم تلفیقی UV و ازن زنی با جریان قالبی در مقیاس آزمایشگاهی انجام گردید. در مرحله اول مطالعه، تاثیر ازن و UV با هم و در مراحل دوم و سوم، تاثیر ازن و UV به طور جداگانه در حذف اسید هیومیک مورد بررسی قرار گرفت.
    یافته ها
    نتایج نشان داد با غلظت اولیه اسید هیومیک 15 میلی گرم در لیتر، pH برابر 8، غلظت ازن تزریقی 5/3 گرم در ساعت، زمان واکنش 25 دقیقه و با حضور UV و ازن، درصد حذف اسید هیومیک 7/74% بدست آمد. این در حالی است که در شرایط مشابه و با کاربرد ازن و UV به تنهایی، به ترتیب 69 و 21 درصد حذف اسید هیومیک حاصل شد.
    نتیجه گیری
    این مطالعه نشان داد که کاربرد ترکیبی UV/O3، کاراتر از بکارگیری ازن و UV به تنهایی می باشد. ازن راندمان بیشتری نسبت به UV در حذف اسید هیومک دارد که می تواند بخاطر قدرت اکسید کنندگی بالای ازن و رادیکال های OH باشد.
    کلید واژگان: اکسیداسیون پیشرفته, UV, O3, اسید هیومیک}
    Ahmadreza Yazdanbakhsh, Mohammadreza Massoudinejad, Sattar Mohammadi*
    Background And Aims
    Humic Acid (HA) is the most important combination of water humic materials. Removal of this compound leads to decreased production of chlorination by-products. This study set out with the aim of assessing the efficiency of O3، UV and UV/O3 in a plug-flow reactor in order to remove HA from water.
    Materials And Methods
    The removal efficiency was assessed at three distinct steps through raw synthetic water samples containing specific concentrations of HA and treated water measurements of humic acid. Experiments were carried out in a laboratory scale plug-flow combined UV and ozonation system. The first question in this study sought to determine the compounded impact of ozone and UV on HA removal. The subsequent second and third questions in this research were to determine the separate effects of ozone and UV on the removal of target compound.
    Results
    HA removal was slightly augmented in simultaneous presence of UV and ozone reaching 74. 7% at initial HA concentration of 15 mg/L، pH 8، and reaction time of 25 min. However، on the question of separate effects of ozone and UV، this study found that the removal rate of HA، at similar situations، were 69% and 21%، respectively.
    Conclusion
    Integrated application of UV and ozone outperformed conventional separate use of them in terms of HA removal. Higher removal efficiencies which achieved during ozone treatment، as compared with UV، might be due to higher oxidation power of ozone and OH radicals.
    Keywords: Advanced Oxidation, UV, Ozonation, Humic Acid}
  • Akbar Eslami, Ahmad Reza Yazdanbakhsh, Mohammad Hassan Momayyezi
    Large amounts of wastewater containing organic and inorganic chemicals from different sources enter the environment, each year. Given the importance of preserving public health andenvironment, efficient technologies like Advanced Oxidation Processes (AOP) should be noted. Ultrasound is an AOP and used as an efficient technology to remove pollutants in recent years.This study aimed to evaluate sonolysis for removing reactive dyes from textile wastewater. This experimental laboratory study utilized composite sampling from textile wastewater for24 hours. First, raw wastewater characteristics were determined. Then, an undivided cell with a volume of 250 ml was used for 200 ml sample of textile wastewater to investigate theSonochemical process. Given the variables, 48 samples were calculated. An ultrasonic bath (power=50 W, frequency=28 kHz) was used. The test results showed that the efficiency of dye removal is increased with decreasing pH and increasing catalyst concentration and retention time. Also, the optimal conditions for effective parameters on the process were obtained such as pH=2, air flow rate of 1 liter per minute, the catalyst concentration 3 mM and retention time 240 minutes at a frequency of 28 kHz and input voltage 50 W. Under these conditions, the efficiency of dye removal was obtained 42.5. According to the results, sonolysis (frequency=28 kHz and power=50 W) can be used as pretreatment to analyze resistant pollutants. Sonolysis is better to be used in combination with other advanced oxidation methods.
    Keywords: Dye, Reactive, Oxidation, Ultrasound, Wastewater}
نمایش عناوین بیشتر...
سامانه نویسندگان
  • احمد رضا یزدانبخش
    یزدانبخش، احمد رضا
    استاد گروه مهندسی بهداشت محیط، دانشکده بهداشت و ایمنی، دانشگاه علوم پزشکی شهیذ بهشتی، دانشگاه علوم پزشکی شهید بهشتی
اطلاعات نویسنده(گان) توسط ایشان ثبت و تکمیل شده‌است. برای مشاهده مشخصات و فهرست همه مطالب، صفحه رزومه ایشان را ببینید.
بدانید!
  • در این صفحه نام مورد نظر در اسامی نویسندگان مقالات جستجو می‌شود. ممکن است نتایج شامل مطالب نویسندگان هم نام و حتی در رشته‌های مختلف باشد.
  • همه مقالات ترجمه فارسی یا انگلیسی ندارند پس ممکن است مقالاتی باشند که نام نویسنده مورد نظر شما به صورت معادل فارسی یا انگلیسی آن درج شده باشد. در صفحه جستجوی پیشرفته می‌توانید همزمان نام فارسی و انگلیسی نویسنده را درج نمایید.
  • در صورتی که می‌خواهید جستجو را با شرایط متفاوت تکرار کنید به صفحه جستجوی پیشرفته مطالب نشریات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال