به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت

فهرست مطالب bhavna ray

  • Batool Albalooshi, Mouza Al Sharhan, Fariborz Bagheri, Shabna Miyanath, Muhammed Muhasin, Bhavna Ray, Seyed Rasoul Zakavi *
    Objective(s)
    99mTc-PSMA SPECT/CT is a cost effective alternative for 68Ga-PSMA PET/CT. The aim of this study was to directly compare these two techniques in patients with prostate cancer.
    Methods
    28 man with prostate cancer were studied using 99mTc-PSMA SPECT/CT and 68Ga-PSMA PET/CT in a short time period (68Ga-PSMA. 99mTc-PSMA kit (PSMA I+S) was used for SPECT/CT and whole body imaging was performed 4 hours after IV injection of 740 MBq of 99mTc-PSMA.  Images were interpreted independently and the results of each imaging were recorded.
    Results
    The mean age of the patients was 64.7±9.6 years old and the mean time difference between two sets of images was 16.6±13.5 days. Abnormal uptake was seen in 25 (89.2%) patients by 68Ga-PSMA PET/CT and 20 (71.4%) patients with 99mTc-PSMA SPECT/CT. No patients with positive 99mTc-PSMA SPECT/CT had negative 68Ga-PSMA PET/CT. The mean number of detected lesions was 26.07±27.5 by 68Ga-PSMA PET/CT and 10.52±10.99 by 99mTc-PSMA SPECT/CT (P<0.001). Detection of lymph nodes and bone metastases were not significantly different between two sets of imaging (P>0.05), however 68Ga-PSMA PET/CT were more successful in detection of prostate bed lesions compared to 99mTc-PSMA scan. Interestingly, no patient with PSA level of >2.1 ng/ml had discordant result between two sets of images.
    Conclusion
    99mTc-PSMA SPECT/CT is as accurate as  68Ga-PSMA PET/CT in M staging, however 68Ga-PSMA PET/CT detected more lesions compared to 99mTc-PSMA SPECT/CT. Detection rate was not significantly different between two techniques in patients with PSA levels>2.1 ng/ml.
    Keywords: Prostate cancer, Tc-99m-PSMA, Ga-68-PSMA}
  • Batool Al Balooshi *, Shabna Miyanath, Amr Elhennawy, Yaser Saeedi, Syed Hammad Tirmazy, Muhammed Muhasin, Bhavna Ray, Mouza Al Sharhan, Hassan Hotait, Yamina Houcinat, Tasnim Keloth
    F-18 FDG is the most widely used tracer in molecular imaging and it is applied for many purposes mainly in malignant diseases. Incidental finding are common in FDG-PET/CT imaging and includes benign and malignant lesions. Among the rare tumors , adrenal oncocytomas are uncommon findings and incidental findings of thyroid malignancies are not rare. Oncocytoma is a rare adrenocortical tumor and majority of bulky adrenal tumors are benign with uncertain incident of malignancy. In this study, we are reporting a 37-year-old man with two incidental malignancies detected by FDG-PET-CT. He has no symptoms has no blood and hormonal abnormalities.
    The scan demonstrated intense heterogeneous FDG uptake within the bulky oval shaped lesion in the left adrenal gland. Accordingly, open adrenalectomy was performed and diagnosis of adrenocortical carcinoma oncocytic type was established. Furthermore, a focal FDG uptake was identified in the right thyroid lobe and histopathology findings were consistent with well-differentiated papillary thyroid cancer. FDG plays a great role in identifying primary rare lesions and also detection of incidental findings at unexpected sites.
    Keywords: F-18 FDG, adrenal mass, adrenocortical carcinoma, thyroid carcinoma, adrenal oncocytoma}
بدانید!
  • در این صفحه نام مورد نظر در اسامی نویسندگان مقالات جستجو می‌شود. ممکن است نتایج شامل مطالب نویسندگان هم نام و حتی در رشته‌های مختلف باشد.
  • همه مقالات ترجمه فارسی یا انگلیسی ندارند پس ممکن است مقالاتی باشند که نام نویسنده مورد نظر شما به صورت معادل فارسی یا انگلیسی آن درج شده باشد. در صفحه جستجوی پیشرفته می‌توانید همزمان نام فارسی و انگلیسی نویسنده را درج نمایید.
  • در صورتی که می‌خواهید جستجو را با شرایط متفاوت تکرار کنید به صفحه جستجوی پیشرفته مطالب نشریات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال