به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت

فهرست مطالب hugo josé santos bastos

  • Key Fabiano Souza Pereira, Lia Beatriz Junqueira-Verardo, Edilson José Zafalon, Luiz Fernando Tomazinho, Vanessa Rodrigues Do Nascimento, Hugo José Santos Bastos, Alex Yoshiharu Otani
    Introduction

    Ultrasonic vibration for metallic post removal seems to be a unanimous choice between endodontists and general practitioners for providing the best results and having the highest safety. This study compared the time required by ultrasonic vibration for removing metallic post (MP) when 1 or 2 ultrasonics devices are used.

    Materials and Methods

    One hundred and fifteen teeth with MPs from 105 patients, indicated for nonsurgical endodontic retreatment were divided into 2 groups according to the number of ultrasonic devices used (G1-1 device) and (G2-2 devices). In G1, the MP was worn with a transmetal bur, alongside the wear of the cement line (around 2 mm deep). Then, an ultrasonic tip attached to an ultrasonic unit, with a power of 100% was activated at the level of the post, with constant water spray at a level of 1 mm above the axial surface of the tooth. The position of the tip was changed between buccal and lingual surfaces every 10 seconds until the MP was removed. In G2 the same procedures were performed as described in G1, but two ultrasonic tips were activated simultaneously at buccal and lingual surfaces until the MP was removed. The vibration time necessary for removing each MP was recorded using a chronometer.

    Results

    The mean time was 131.10±29.68 seconds (mean±standard error of the mean) for MP removal using one ultrasonic device, and 24.86±6.88 seconds for two devices. The time required for MP removal using two ultrasonic devices was significantly less than when using one ultrasonic device (P<0.001).

    Conclusion

    The technique with 2 ultrasonic devices proved to be more efficient than the one using only 1 ultrasonic device.

    Keywords: Endodontics, Metallic Post Removal, Post, Core Technique, Retreatment, Ultrasonic Vibration}
  • Key Fabiano Souza Pereira, Samara Ortiz da Silva, Hugo Jose Santos Bastos, Luiz Fernando Tomazinho, Vanessa Rodrigues do Nascimento, Lia Beatriz Junqueira -Verardo, Alex Yoshiharu Otani

    Bioceramic cements used for filling root canals in cases of endo-perio lesion of endodontic origin seem to be promising due to having the potential of promoting faster and more predictable healing of the periapical lesion as they stimulate osteogenesis. An effectivetreatment plan depends on the precise diagnosis of endo-perio lesions. The origin of an infection, being exclusive to the root canal, from the periodontium, or both, is extremely important for devising the treatment plan. In both cases, no clinical evidence of periodontal disease (bleeding, calculus, etc.) was found; however, primary endodontic lesions with the possibility of drainage through the gingival crevice were present. In addition to the disinfection strategies used during the root canal treatments, the bioceramics Bio C Sealer, Bio C Repair and Bio Root RCS were used to fill in the root canals. Both cases presented an impressive bone gain within 8 months for case 1 and 5 months for case 2. Regarding case 1, in the palatal root canal an apical plug with a bioceramic repair cement was used. Based on the literature studied, it can be concluded that after adequate disinfection of the root canals, using bioceramic cements in filling the root canals shows the potential of supporting capabilities in remineralization of osteolytic lesions in endo-perio diseases.

    Keywords: Calcium Silicate, Endodontics, Endodontic-periodontal Lesion, Periodontics}
بدانید!
  • در این صفحه نام مورد نظر در اسامی نویسندگان مقالات جستجو می‌شود. ممکن است نتایج شامل مطالب نویسندگان هم نام و حتی در رشته‌های مختلف باشد.
  • همه مقالات ترجمه فارسی یا انگلیسی ندارند پس ممکن است مقالاتی باشند که نام نویسنده مورد نظر شما به صورت معادل فارسی یا انگلیسی آن درج شده باشد. در صفحه جستجوی پیشرفته می‌توانید همزمان نام فارسی و انگلیسی نویسنده را درج نمایید.
  • در صورتی که می‌خواهید جستجو را با شرایط متفاوت تکرار کنید به صفحه جستجوی پیشرفته مطالب نشریات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال