به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت
فهرست مطالب نویسنده:

kristin m. hammersmith

  • Remzi Karadag*, Kristin M. Hammersmith, Parveen K. Nagra, Christopher J. Rapuano
    Purpose

    To compare anterior segment parameters in patients with Fuchs endothelial dystrophy (FED) who underwent Descemet stripping automated endothelial keratoplasty (DSAEK) in one eye and no corneal surgery in the fellow eye.

    Methods

    This prospective study was conducted on 28 eyes of 14 patients with FED who underwent DSAEK in one eye at least one year prior (DSAEK group) and no corneal surgery in the fellow eye (control group). Each eye was analyzed with the anterior segment optical coherence tomography, specular microscopy, and Scheimpflug imaging systems. Data were compared between the two groups.

    Results

    The mean age of the patients was 76.9 ± 7.0 years. There were no statistically significant differences in the mean central corneal thickness (CCT), central anterior chamber depth, anterior chamber angle parameters, cylinder and keratometry values between two groups (all P-values > 0.05). The paracentral corneal thickness, corneal volume, endothelial cell density, and hexagonal cell ratio measurements were statistically significantly higher in the DSAEK group than the control (all P-values < 0.05), and anterior chamber volume in the DSAEK group was significantly less than the control (P = 0.046). While posterior and total corneal densitometry values in the DSAEK group were statistically significantly lower than the control (P < 0.001 and P = 0.011, respectively), there were no statistically significant differences in the anterior or middle corneal densities (P = 0.108 and P = 0.134, respectively).

    Conclusion

    We found that total corneal densitometry value decreased in DSAEK group. Although DSAEK surgery did not affect the anterior chamber angle parameters, it reduced the anterior chamber volume and increased the corneal volume and paracentral corneal thickness due to the addition of the DSAEK graft.

    Keywords: Anterior Chamber Parameters, Corneal Densitometry, Corneal Thickness, Descemet Stripping Automated Endothelial Keratoplasty, DSAEK, Endothelial Cell, FuchsDystrophy
بدانید!
  • در این صفحه نام مورد نظر در اسامی نویسندگان مقالات جستجو می‌شود. ممکن است نتایج شامل مطالب نویسندگان هم نام و حتی در رشته‌های مختلف باشد.
  • همه مقالات ترجمه فارسی یا انگلیسی ندارند پس ممکن است مقالاتی باشند که نام نویسنده مورد نظر شما به صورت معادل فارسی یا انگلیسی آن درج شده باشد. در صفحه جستجوی پیشرفته می‌توانید همزمان نام فارسی و انگلیسی نویسنده را درج نمایید.
  • در صورتی که می‌خواهید جستجو را با شرایط متفاوت تکرار کنید به صفحه جستجوی پیشرفته مطالب نشریات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال