به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت
فهرست مطالب نویسنده:

mehdi ahadi barzoki

  • Kheirollah Gholami, Mohammadreza Rouini, Niayesh Mohebbi, Iman Karimzadeh, Mehdi Ahadi Barzoki, Mahboob Lessan, Pezeshki, Saeed Rezaee
    Background
    The purpose of this study was to characterize the pharmacokinetic parameters of mycophenolic acid (MPA) in Iranian kidney transplant patients.
    Methods
    Plasma MPA concentration of mycophenolate mofetile (MMF) 1 gram two times a day was measured in 21 Iranian kidney transplant recipients receiving treatment. Patients who entered the study had been transplanted for more than 3 months and their drug level was supposed to be at steady state. MMF concentration was measured with high-performance liquid chromatography (HPLC).
    Results
    The plasma MPA concentration-time curve was characterized by an early sharp peak at about 1 hour postdose. The mean Area Under Curve (AUC), Cmax and Tmax were 47.0±18.3 µg.h/ml, 18.6±8.5 µg/ml and 1.0±0.5 hours respectively.
    Conclusion
    The plasma MPA concentration-time curve pattern of Iranian patients was similar and consistent with previously reported profiles in other populations taking the same dose.
    Keywords: Mycophenolate mofetil, Mycophenolic acid, Pharmacokinetics, Area Under Curve, Kidney transplantation
  • Mehdi Ahadi Barzoki, Mohammadreza Rouini, Kheirolla Gholami, Mahboob Lessan, Pezeshki, Saeed Rezaee
    A simple, sensitive and reproducible HPLC method is presented for determination of mycophenolic acid(MPA) in human plasma. Samples were prepared after precipitation of the plasma protein by addition of acetonitrile and naproxen was used as internal standard (I.S.). Separation was performed by reversedphase HPLC, using a Hamilton PRP-C18 Column, 51% acetonitrile and 49% potassium phosphate buffer (20 mM) at pH 3.0 as mobile phase, flow rate of 1.0 ml/min, and UV detection at 215 nm. MPA and I.S. had retention times of 7.5 and 11.35 min, respectively. The method showed an acceptable linearity in the range of 0.1µg/ml-40µg/ml with r2 of. 9992. The concentration of 0.1µg/ml was determined as quantification limit. Mean absolute recovery was 94.8%. The mean intra- and inter-day reproducibility of method was 4.6 and 11.4% respectively.
بدانید!
  • در این صفحه نام مورد نظر در اسامی نویسندگان مقالات جستجو می‌شود. ممکن است نتایج شامل مطالب نویسندگان هم نام و حتی در رشته‌های مختلف باشد.
  • همه مقالات ترجمه فارسی یا انگلیسی ندارند پس ممکن است مقالاتی باشند که نام نویسنده مورد نظر شما به صورت معادل فارسی یا انگلیسی آن درج شده باشد. در صفحه جستجوی پیشرفته می‌توانید همزمان نام فارسی و انگلیسی نویسنده را درج نمایید.
  • در صورتی که می‌خواهید جستجو را با شرایط متفاوت تکرار کنید به صفحه جستجوی پیشرفته مطالب نشریات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال