به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت

فهرست مطالب mehmet ozdemir

  • Mustafa Altindis *, Mehmet Koroglu, Tayfur Demiray, Tuba Dal, Mehmet Ozdemir, Ahmet Zeki Sengil, Ali Riza Atasoy, Metin Turan, Aysegul Copur Cicek, Gulfem Ece, Selcuk Kaya, Meryem Iraz, Bilge Sumbul Gultepe, Hakan Temiz, Idris Demirkan
    Background
    The prognostic value of blood culture testing in the diagnosis of bacteremia is limited by contamination..
    Objectives
    In this multicenter study, the aim was to evaluate the contamination rates of blood cultures as well as the parameters that affect the culture results..
    Materials And Methods
    Sample collection practices and culture data obtained from 16 university/research hospitals were retrospectively evaluated. A total of 214,340 blood samples from 43,254 patients admitted to the centers in 2013 were included in this study. The blood culture results were evaluated based on the three phases of laboratory testing: the pre-analytic, the analytic, and the post-analytic phase..
    Results
    Blood samples were obtained from the patients through either the peripheral venous route (64%) or an intravascular catheter (36%). Povidone-iodine (60%) or alcohol (40%) was applied to disinfect the skin. Of the 16 centers, 62.5% have no dedicated phlebotomy team, 68.7% employed a blood culture system, 86.7% conducted additional studies with pediatric bottles, and 43.7% with anaerobic bottles. One center maintained a blood culture quality control study. The average growth rate in the bottles of blood cultures during the defined period (1259 - 26,400/year) was 32.3%. Of the growing microorganisms, 67% were causative agents, while 33% were contaminants. The contamination rates of the centers ranged from 1% to 17%. The average growth time for the causative bacteria was 21.4 hours, while it was 36.3 hours for the contaminant bacteria. The most commonly isolated pathogens were Escherichia coli (22.45%) and coagulase-negative staphylococci (CoNS) (20.11%). Further, the most frequently identified contaminant bacteria were CoNS (44.04%)..
    Conclusions
    The high contamination rates were remarkable in this study. We suggest that the hospitals’ staff should be better trained in blood sample collection and processing. Sterile glove usage, alcohol usage for disinfection, the presence of a phlebotomy team, and quality control studies may all contribute to decreasing the contamination rates. Health policy makers should therefore provide the necessary financial support to obtain the required materials and equipment..
    Keywords: Blood Specimen Collection, Phlebotomy, Blood, Borne Pathogens, Bacteriological Techniques}
بدانید!
  • در این صفحه نام مورد نظر در اسامی نویسندگان مقالات جستجو می‌شود. ممکن است نتایج شامل مطالب نویسندگان هم نام و حتی در رشته‌های مختلف باشد.
  • همه مقالات ترجمه فارسی یا انگلیسی ندارند پس ممکن است مقالاتی باشند که نام نویسنده مورد نظر شما به صورت معادل فارسی یا انگلیسی آن درج شده باشد. در صفحه جستجوی پیشرفته می‌توانید همزمان نام فارسی و انگلیسی نویسنده را درج نمایید.
  • در صورتی که می‌خواهید جستجو را با شرایط متفاوت تکرار کنید به صفحه جستجوی پیشرفته مطالب نشریات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال