به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت

فهرست مطالب neelam chandwani

  • Neelam Chandwani, Aastha Ranka, Ganesh R Jadhav, Dolly Jagyasi, Pooja Bopche, Arihant Golchha
    Background

    The aim of this study was to compare dentinal crack formation in root canal walls following 3 single file systems with continuous rotation under a scanning electron microscope (SEM).

    Materials and Methods

    In this SEM study, seventy mandibular premolars were randomly divided into 5 groups. 3 experimental groups (n = 20) and 2 control groups (n = 5) as follows: Group I: Neolix NiTi file system, Group II: OneShape systems, Group III: OneCurve file system, positive control: conventional Hand File system, negative control: unprepared. After root canal preparations, the roots were sectioned at 3, 6, and 9 mm from the apex with water irrigation. The sections were inspected in all directions under SEM at × 100 magnification to determine the presence of cracks. The Chi‑square test was used to analyze the data. There is a statistically significant difference in the crack formation between the apical third (P = 0.012) and coronal third (P = 0.002) when comparing all the 5 groups. No significant difference is found in the middle third (P = 0.46). P < 0.05 is considered statistically significant.

    Results

    Maximum cracks in the apical third were seen with One Shape file 11 (55%) and in the coronal third with Neolix NiTi 14 (70%). There is a statistically significant difference in the crack formation only in OneCurve when comparing the apical, middle, and coronal third for the individual group (P = 0.042).

    Conclusion

    There was a significant difference in crack formation in apical and coronal third. OneCurve caused the least incidence of cracks when compared to other file systems. OneCurve file system can be a choice for canal preparation over Neolix Niti and OneShape.

    Keywords: Dentin, electron scanning microscopy, endodontics, nickel–titanium alloy, rootcanal}
بدانید!
  • در این صفحه نام مورد نظر در اسامی نویسندگان مقالات جستجو می‌شود. ممکن است نتایج شامل مطالب نویسندگان هم نام و حتی در رشته‌های مختلف باشد.
  • همه مقالات ترجمه فارسی یا انگلیسی ندارند پس ممکن است مقالاتی باشند که نام نویسنده مورد نظر شما به صورت معادل فارسی یا انگلیسی آن درج شده باشد. در صفحه جستجوی پیشرفته می‌توانید همزمان نام فارسی و انگلیسی نویسنده را درج نمایید.
  • در صورتی که می‌خواهید جستجو را با شرایط متفاوت تکرار کنید به صفحه جستجوی پیشرفته مطالب نشریات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال