  • Yazdan Ashgevari *, Aref Jalili Irani, Nader Badali Barooq, Aref Najafinejad

    Phase Unbalance in distribution networks is one of the unavoidable problems that results from presence of single-phase charges and diversity of consumption among customers. This paper aims to study unusable capacity in distribution transformers due to phase Unbalance through proposing a new coefficient for estimating their capacity. In this study, the primary reasons which lead to Unbalance in transformers have been studied, then unusable capacity in transformers and phase Unbalance index have been formulated , and finally, real results on two posts related to Ardabil electricity distribution network have been evaluated, information corresponded to sample posts has been acquired through installing data logger machine, type TDL 104 for a week and using hour-to-hour sampling method. The results form machine have been analyzed using Matlab software, and then related diagrams have been drawn and also comparison among them has been done. Finally, the effect of phase Unbalance in estimating transformers’ capacity has been proposed by a coefficient.

    Keywords: Phase Unbalance, Phase Unbalance Index, Capacity of Distribution Transformers
  • سجاد احمدی، هامون پورروشنفکر عربانی، دنیا آشتیانی حقیقی، جوزپ ام گوئریرو، یزدان اشکواری، عادل اکبری مجد*

    ددر این مقاله، جایابی بهینه ی چندهدفه ی واحد های اندازه گیر فازوری در سیستم قدرت ارایه می شود که دو هدف را به طور همزمان بهینه می کند. هدف اول کمینه کردن هزینه کلی نصب تجهیزات که معادل کمینه کردن تعداد واحدهای اندازه گیر فازوری نصب شده در شبکه، و هدف دوم بیشینه کردن شاخص افزونگی اندازه گیری سیستم که معادل بیشینه کردن قابلیت اطمینان سیستم است. همچنین در این تحقیق مسئله ی تاثیر محدودیت تعداد کانال های اندازه گیری واحدهای اندازه گیر فازوری و اثر شین تزریق صفر مورد بررسی قرار می گیرد. در سیستم های قدرت، تپ ترانسفورماتور به عنوان یکی از ابزارهای تنظیم ولتاژ شبکه بکار می رود که در اکثر مواقع سیگنال تغییر این پارامتر به مرکز کنترل شبکه ارسال نمی شود. این امر موجب اختلال جدی در عملکرد برنامه تخمین حالت می گردد. در نتیجه مشاهده پذیری تپ ترانسفورمر باید در مسئله ی جایابی واحدهای اندازه گیر فازوری در سیستم قدرت لحاظ گردد. بدین منظور یک شین مجازی به شبکه اضافه شده تا بتوان تپ متغیر ترانسفورمر را در آن مدل نمود.  با توجه به مزایای روش های فراابتکاری از الگوریتم گرگ خاکستری با ساختار چندهدفه مبتنی بر مفهوم غلبه و بهینه ی پارتو برای حل مسئله استفاده می شود.

    کلید واژگان: واحد های اندازه گیری فازور, افزونگی اندازه گیری, محدودیت تعداد کانال, شین تزریق صفر, الگوریتم گرگ خاکستری
    Sajjad Ahmadi, Hamoun Pourroshanfekr Arabani, Donya Ashtiani Haghighi, Josep M. Guerrero, Yazdan Ashgevari, Adel Akbarimajd*

    In this paper, the multi-objective PMU placement is presented. Two objectives are fulfilled simultaneously which are the minimization of the equipment installation cost (i.e. minimizing the number of installed PMUs) along with the maximization of the system measure redundancy index which is equal to the maximization of system’s reliability. Moreover, the limitation on the number of PMU measurement channels is investigated for fulfilling the total system observability and increasing the measurement redundancy. In a power system, transformers tap is employed as an equipment for voltage regulation, however, the variation signal of this parameter is not mostly sent to the central control which leads to a severe disturbance in state estimation program. Consequently, transformers tap observability should be considered in PMU placement problem. Accordingly, a virtual bus is added to the grid in order to model the variant transformer tap. Due to the advantages of meta-heuristic methods, the multi-objective Gray wolf algorithm based on dominancy and Pareto criteria concepts is applied.

    Keywords: Phasor measurement units, Measuring Redundancy, Zero injection bus, Limitation on the channel number, GWO algorithm
  • Nader Hasan Badali Barough, Yazdan Ashgevari, Aref Jalili Irani, Aref Najafinejad, Saeid Bairami
    Phase Unbalance in distribution networks is one of the unavoidable problems that results from presence of single-phase charges and diversity of consumption among customers. This paper aims to study unusable capacity in distribution transformers due to phase Unbalance through proposing a new coefficient for estimating their capacity. In this study, the primary reasons which lead to Unbalance in transformers have been studied, then unusable capacity in transformers and phase Unbalance index have been formulated, and finally, real results on two posts related to Ardabil electricity distribution network have been evaluated, information corresponded to sample posts has been acquired through installing data logger machine, type TDL 104 for a week and using hour-to-hour sampling method. The results form machine have been analyzed using Matlab software, and then related diagrams have been drawn and also comparison among them has been done. Finally, the effect of phase Unbalance in estimating transformers’ capacity has been proposed by a coefficient.