به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت

جستجوی مقالات مرتبط با کلیدواژه "meps method" در نشریات گروه "شیمی"

تکرار جستجوی کلیدواژه «meps method» در نشریات گروه «علوم پایه»
جستجوی meps method در مقالات مجلات علمی
  • Nematullah Kurd, Abdulrahman Bahrami *, Abbas Afkhami, Farshid Ghorbani Shahna, Mohammadjavad Assari, Maryam Farhadian

    A new and fast sample preparation method was developed to extract Hippuric acid (HA), Trans,trans-muconic acid (tt-MA), Mandelic acid (MA), and m-Methylhippuric acid (m-MHA) in urine samples using Hollow polymer nanospheres (HPSs), Covalent organic frameworks (COFs), and their mixture (HPS:COF) as an adsorbent, combined with high-performance liquid chromatography-ultraviolet spectrophotometry (HPLC-UV). X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), and transmission electron microscopy (TEM) were used to study the features of the adsorbents. The effect of important factors such as temperature and pH of the sample, amount of sorbent, conditioning and washing solvents, type and volume of desorption solvent, sample volume, and the number of extraction cycles were investigated to achieve the optimal conditions with microextraction by packed sorbent (MEPS) procedure. The applicability of the proposed method was then validated in the laboratory. Finally, the target analytes in the urinary samples of gas station workers were examined. The data analysis showed that using an HPS:COF mixture improves the extraction efficiency in optimal conditions compared to the case where the COF adsorbent is used alone (extraction efficiency, 81-87.5%). Also, a good linear dynamic range (0.1-1000 µg/mL for m-MHA), a low detection limit (0.02 µg/mL for tt-MA), and acceptable intra-day and inter-day precision (1.4-3.6 % and 4.5-8.9 %, respectively) were obtained under similar conditions. Overall, HPS: COF-MEPS exhibited excellent extraction efficiency (85.4-93.3%) and has the potential to replace previous methods in the biomonitoring of BTEX biomarkers in urine.

    Keywords: BTEX biomarkers, HPSs: COF adsorbent, HPLC-UV, MEPS method, Urine samples
نکته
  • نتایج بر اساس تاریخ انتشار مرتب شده‌اند.
  • کلیدواژه مورد نظر شما تنها در فیلد کلیدواژگان مقالات جستجو شده‌است. به منظور حذف نتایج غیر مرتبط، جستجو تنها در مقالات مجلاتی انجام شده که با مجله ماخذ هم موضوع هستند.
  • در صورتی که می‌خواهید جستجو را در همه موضوعات و با شرایط دیگر تکرار کنید به صفحه جستجوی پیشرفته مجلات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال