به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت

جستجوی مقالات مرتبط با کلیدواژه "cyclodextrines" در نشریات گروه "پزشکی"

جستجوی cyclodextrines در مقالات مجلات علمی
  • Gabriel Hancu*, Monica Budau, Lajos Kristof Kantor, Anca Carje
    Purpose
    Amlodipine is a long acting, dihydropyridine type calcium channel blocker frequently used in the treatment of hypertension and coronary insufficiency. The calcium channel blocking activity resides primarily in the S-amlodipine enantiomer, while R-amlodipine is a potent inhibitor of smooth muscle cell migration.
    Methods
    In this study capillary electrophoresis was applied for the enantiomeric separation of amlodipine using different native and derivatized; neutral and charged cyclodextrines as chiral selectors. The effects of pH and composition of the background electrolyte, concentration and type of chiral selector, capillary temperature, running voltage and injection parameters have been investigated.
    Results
    Stereoselective interactions were observed when using α-CD, β-CD, HP-β-CD, RAMEB, CM-β-CD and SBE-β-CD. Optimized separation conditions consisted on a 50 mM phosphate buffer, pH – 3.0, 20 mM RAMEB as chiral selector, + 25 kV applied voltage, 15°C temperature and UV detection at 238 nm. Using the optimized electrophoretic conditions we succeeded the chiral separation of amlodipine enantiomers in approximately 6 minute, the order of migration being R-amlodipine followed by S-amlodipine. The method was successfully applied for the determination of amlodipine enantiomers from commercially available pharmaceuticals. The linearity range, limits of detection and quantification, precision and accuracy were determined and the results obtained confirmed that the method was suitable for this purpose.
    Conclusion
    It can be concluded that the proposed capillary electrophoresis methods can be useful for routine pharmaceutical applications with benefits of its effectivity, simplicity, short analysis time and low consumption of analytes, solvents and chiral selectors.
    Keywords: Amlodipine, Capillary electrophoresis, Chiral Separation, Cyclodextrines
  • Gabriel Hancu, Anca CÂrje, Ileana Iuga, Ibolya FÜl, Oumlp., Zolt, Aacute, N. Istvan Szab, Oacute
    Carvedilol is administered as a racemic mixture of the R(+)- and S(-)-enantiomers, although it was demonstrated that the two enantiomers exhibit different pharmacological effects and stereoselective pharmacokinetics. The aim of this study was the evaluation of several native and derivatized cyclodextrines as chiral selectors for the separation of carvedilol enantiomers. Stereoselective interactions were observed with four cyclodextrines (β-CD, hydroxypropyl-β-CD, randomly methylated β-CD and sulfobuthyl ether- β-CD). The effects of CD concentration, pH value and composition of the background electrolyte, capillary temperature, running voltage and injection parameters have been investigated. The method was validated for precision of peak-area response, linearity range and limits of detection and quantification. An efficient stereoselective capillary zone electrophoretic method was developed for the determination of carvedilol enantiomers using a simple 25 mM phosphate buffer at a pH = 2.5 and 10 mM β-CD as chiral selector, resulting in baseline separation of the two enantiomers with sharp peaks and relatively short analysis time. Highly satisfactory results were obtained from the analysis of carvedilol from tablets, indicating that the method is suitable for routine analysis of carvedilol in pharmaceutical products.
    Keywords: carvedilol, Capillary Electrophoresis, chirality, cyclodextrines, enantiomer separation
  • Amelia Tero, Vescan, Gabriel Hancu*, Mihaela Oroian, Anca CÂrje
    Purpose
    Indapamide is probably the most frequently prescribed diuretic drug, generally being used for the treatment of hypertension. It contains a chiral center in its molecule; is marketed as a racemic mixture; but there are rather few studies regarding the pharmacokinetic and the pharmacological effect differences of the two enantiomers. Our aim was the development of a simple, rapid and precise analytical procedure for the chiral separation of indapamide enantiomers.
    Methods
    In this study capillary zone electrophoresis was used for the enantiomeric separation of indapamide using a systematic screening approach involving different native and derivatized; neutral and charged cyclodextrines as chiral selectors. The effects of pH value and composition of the background electrolyte, capillary temperature, running voltage and injection parameters have been investigated.
    Results
    After preliminary analysis a charged derivatized CD, sulfobuthyl ether- β-CD, proved to be the optimum chiral selector for the enantioseparation. Using a buffer solution containing 25 mM disodium hydrogenophosphate – 25 mM sodium didydrogenophosphate and 5 mM sulfobuthyl ether- β-CD as chiral selector at a pH - 7, a voltage of + 25 kV, temperature 15°C and UV detection at 242 nm, we succeeded in the separation of the two enantiomers in approximately 6 minutes, with a resolution of 4.30 and a separation factor of 1.08.
    Conclusion
    Capillary zone electrophoresis using cyclodextrines as chiral selectors proved to be a suitable method for the enantioseparation of indapamide. Our method is rapid, specific, reliable, and cost-effective and can be proposed for laboratories performing indapamide routine analysis.
    Keywords: Indapamide, Capillary electrophoresis, Chiral separation, Cyclodextrines
نکته
  • نتایج بر اساس تاریخ انتشار مرتب شده‌اند.
  • کلیدواژه مورد نظر شما تنها در فیلد کلیدواژگان مقالات جستجو شده‌است. به منظور حذف نتایج غیر مرتبط، جستجو تنها در مقالات مجلاتی انجام شده که با مجله ماخذ هم موضوع هستند.
  • در صورتی که می‌خواهید جستجو را در همه موضوعات و با شرایط دیگر تکرار کنید به صفحه جستجوی پیشرفته مجلات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال