به جمع مشترکان مگیران بپیوندید!

تنها با پرداخت 70 هزارتومان حق اشتراک سالانه به متن مقالات دسترسی داشته باشید و 100 مقاله را بدون هزینه دیگری دریافت کنید.

برای پرداخت حق اشتراک اگر عضو هستید وارد شوید در غیر این صورت حساب کاربری جدید ایجاد کنید

عضویت

جستجوی مقالات مرتبط با کلیدواژه « ultrasonography mammary » در نشریات گروه « پزشکی »

  • Jirapa Chansangrat *, Nattawut Keeratibharat
    Background

    The Breast Imaging-Reporting and Data System (BI-RADS), developed to standardize mammographic findings, categorizes 'probably benign' lesions as BI-RADS 3, aiming to reduce unnecessary biopsies from false positives, with a cancer likelihood of less than 2%. In some countries, screening programs have been expanded to include ultrasound alongside mammography, particularly in populations with predominantly dense breast tissue, leading to an increased detection of BI-RADS 3 lesions through this additional modality. This study examines the effectiveness of 6-month follow-ups for these ultrasound-identified BI-RADS 3 lesions.

    Methods

    We retrospectively analyzed 7,577 women who underwent mammography and ultrasound screening from January 2016 to December 2021. Of these, 2,907 were classified as BI-RADS 3 based on ultrasound findings. The study focused on 1,163 patients with normal mammography and assessed BI-RADS 3 from ultrasound findings, who completed a 24-month follow-up. Data analysis included assessing demographic data, breast cancer risk, imaging features, and pathological findings.

    Results

    Among the 1,163 patients, the cancer detection of the entire cohort was 0.7%, with no cancers detected during the first six months. The cancer found at 6 months and 12-24 months were 0 and 0.17%, respectively (P<0.001). The median time for reassessment from BI-RADS 3 to BI-RADS 4 was 18.4 months. Upon the change of BI-RADS, spiculation and angular margins were the most predictive ultrasound features for malignancy. Lesion size growth alone was found insufficient as a biopsy criterion. A 28% growth cutoff distinguished between benign and malignant lesions better than a 20% cutoff.

    Conclusion

    A 12-month follow-up interval may be more appropriate than the traditional 6-month interval for average-risk patients with BI-RADS 3 lesions detected by screening ultrasound. Combining suspicious imaging features with size increases enhances diagnostic accuracy, providing a tailored follow-up approach based on individual risk profiles and imaging characteristics.

    Keywords: Breast Neoplasms, Diagnostic Screening Programs, Ultrasonography Mammary, Image-Guided Biopsy}
نکته
  • نتایج بر اساس تاریخ انتشار مرتب شده‌اند.
  • کلیدواژه مورد نظر شما تنها در فیلد کلیدواژگان مقالات جستجو شده‌است. به منظور حذف نتایج غیر مرتبط، جستجو تنها در مقالات مجلاتی انجام شده که با مجله ماخذ هم موضوع هستند.
  • در صورتی که می‌خواهید جستجو را در همه موضوعات و با شرایط دیگر تکرار کنید به صفحه جستجوی پیشرفته مجلات مراجعه کنید.
درخواست پشتیبانی - گزارش اشکال