Objective:
The aim of this study was to evaluate the use of endovascular intervention in managing native and recurrent aortic coarctation in adult patients.
Methods:
Balloon angioplasty was undertaken transfemorally in 16 patients (mean age 18.3 ± 4 years old) with arterial hypertension in 12 native and 4 recurrent aortic coarctations. Systolic pressure gradient measurements were taken peri-interventionally and in the course of follow-up during conventional angiography and transesophageal echocardiography. The average diameters of the balloon catheters used ranged from 15 to 20 mm.
Result:
lmmiediately after aortic angioplasty, the peak systolic pressure gradient decreased from 61 mmHg ± 5.4 to 7.6 mmHg ± 2.2 across the coarctation (P < 0.001). One patient With recoarctation had an unsuccessful immediate result. Restenosis occurred in two patients, who subsequently underWent repeat dilation with successful results. Transesophageal echocardiography was repeated post-procedure and at 6 months post-intervention. One patient developed a small aneurysm at the site of dilation. In the course of follow-up, no other major or minor complications were observed.
Conclusion:
Endovascular intervention appears to be a safe and effective alternative to surgery for the treatment of native and recurrent aortic coarctation in most adult patients with a low rate of complications
Keywords: AORTIC ANGIOPLASTY, Hypertension, Aortic Coarctation}