Investigating Accordance of NST Results Stimulated by Vibroacoustic and Halogen Light and BPP in Fetal Wellbeing Assessment

Message:
Abstract:
Introduction
Non-stress test (NST) is one of the most common tools for assessment of fetal wellbeing that has reactive and non-reactive results. Although it is limited by a high rate of false-positive results. This study was aimed to evaluate the accordance of NST results stimulated by vibroacoustic and halogen light and biophysical profile (BPP).
Methods
This clinical trial was held in 2010 on 100 pregnant women referred to Mirza Koochak Khan Hospital for NST. In the cases of 20-minute non-reactive fetal heart rate pattern، women were allocated in vibroacoustic group (N=50، who received vibration from a standard fetal vibratory stimulator)، and halogen light group (N=50، who received from a halogen light source. (In vibroacoustic group، a vibration stimulator with a frequency of 80 Hz for 3 seconds and in halogen light group، the halogen light source with a million candle power by a flashlight for 10 seconds were applied on the maternal abdomen and above the fetal head. Afterward، fetal heart rate was recorded. Stimulated NST results were compared with BPP results. Gathered data were analyzed by SPSS software version 18. P value less than 0. 05 was considered statistically significant.
Results
Two study groups were similar in terms of demographic characteristics such as maternal age (p=0. 425)، gestational age (p=0. 271)، body mass index (p=0. 205) educational level (p=0. 736) and the non-stress test (p=0. 053). No statistical significant difference was observed between them. 68 and 62 percent change of a non-reactive to reactive status was occurred in halogen light group and vibroacoustic group، respectively. Both groups had the same diagnostic values such as positive and negative predictive values، specificity، and sensitivity. There was no significant relation between stimulus NSTs and BPPs.
Conclusion
To improve the results of non-stress test، vibroacoustic and light stimulations can be used as an assistive method along with common NST. Since in most cases، despite the improved NST، a reliable biophysical profile score is obtained، non-reactive pattern followed by external stimulation indicates no fetal risk.
Language:
Persian
Published:
Iranina Journal of Obstetrics Gynecology and Infertility, Volume:15 Issue: 19, 2012
Page:
19
https://magiran.com/p1046279  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!