Correlation of Arterial Blood Gas Measurements with Venous Blood Gas Values in Mechanically Ventilated Patients

Message:
Abstract:
Background
Arterial blood gas (ABG) analysis is useful in evaluation of the clinical condition of critically ill patients; however, arterial puncture or insertion of an arterial catheter may cause many complications. The aim of this study was to determine whether venous blood gas (VBG) values can be used as an alternative to arterial blood gas measurements in patients under mechanical ventilation.
Materials And Methods
This study was carried out on patients admitted to the Intensive Care Unit of Kashan Beheshti Hospital. Blood for VBG analysis was obtained from the cubital vein, while for ABG analysis blood was taken simultaneously from the radial artery. ABG and VBG samples were obtained simultaneously, and indexes of pH, PCO2, HCO3, base excess (BE), PO2 and O2 saturation level were analyzed.
Results
A total of 102 pair of simultaneous venous and arterial blood samples were obtained from 102 patients (mean age 58.4±21.5 years). Seventy (69%) were males. The mean difference between arterial and venous values was 0.04 for pH, 5.6 mm/Hg for PCO2, -0.32 mmol/l for HCO3, -1.03 mmol/l for BE, 53.6 mm/Hg for PO2, and 23.5 % for O2 saturation. The Pearson correlation coefficients between arterial and venous values for pH, PCO2, HCO3, BE, PO2 and O2 saturation were 0.874, 0.835, 0.768, 0.810, 0.287, and 0.310, respectively. Linear regression equations for the estimation of pH, PCO2, HCO3, BE, PO2 and O2 saturation were as follows: arterial pH=1.927+0.745×venous pH [r=0.801, p<0.001]; PCO2=6.470+0.706×venous PCO2 [r=0.835, p<0.001]; arterial HCO3=7.455+0.681×venous HCO3 [r=0.768, p<0.001]; arterial BE=- 0.952+0.736×venous BE [r=0.810, p<0.001]; arterial PO2=70.374+0.620×venousPO2 [r=0.287, p=0.003]; arterial venous saturation= 89.753+0.082×venous O2 saturation [r=0.317, p = 0.001].
Conclusion
Venous blood gases, especially pH, Base excess, and PCO2 levels have relatively good correlation with ABG values. Because this correlation is not close, VBG cannot substitute ABG in mechanically ventilated patients.
Language:
English
Published:
Tanaffos Respiration Journal, Volume:11 Issue: 4, Autumn 2012
Page:
30
https://www.magiran.com/p1095906  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با ثبت ایمیلتان و پرداخت حق اشتراک سالانه به مبلغ 1,390,000ريال، بلافاصله متن این مقاله را دریافت کنید.اعتبار دانلود 70 مقاله نیز در حساب کاربری شما لحاظ خواهد شد.

پرداخت حق اشتراک به معنای پذیرش "شرایط خدمات" پایگاه مگیران از سوی شماست.

اگر مقاله ای از شما در مگیران نمایه شده، برای استفاده از اعتبار اهدایی سامانه نویسندگان با ایمیل منتشرشده ثبت نام کنید. ثبت نام

اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!