Thermal Effects of Laser-osteotomy on Bone: Mathematical Computation Using Maple

Message:
Abstract:
In recent years, interest in medical application of lasers especially as a surgical alternative is considerably increasing due to their distinct advantages such as non-contact intervention, bacteriostasis, less traumatization, minimal invasiveness, decreased bleeding and less heat damage. The present study aimed to evaluate the temperature changes and the consequent released thermal stress in cortical bone caused by an Erbium:yttrium aluminum garnet (Er:YAG) laser (Fideliss 320A, Fotona Inc., Deggingen, Germany) during osteotomy, using mathematical computation by means of Maple software, version 9.5 (Maplesoft, a division of Waterloo Maple Inc., Canada). The results obtained here were compared with the experimental measurements using Er:YAG laser in the osteotomy clinics. A bone slab with thickness of 1 mm was simulated in Maple software. Then, an Er:YAG laser emitting 100 μs pulses at a wavelength of 2940 nm were modeled. Two different clinical settings of the Er:YAG laser with 200 mJ and 400 mJ energies, both with 100 μs exposure and 500 μs silence were studied. To investigate the temperature distribution in the cortical bone, the time-dependent heat conduction equations were defined and solved in the Maple software. Finally, by defining the heat distribution function in the Maple, thermal stress in the bone was investigated. Results of the computations showed that, on the bone irradiated area (center of the bone surface) the maximum temperature rise was 0.8°C and 1.6°C, for 200 mJ and 400 mJ Er:YAG laser exposure, respectively. The temperature rise reached to its minimum at radial distances of 1.2 cm from the point of irradiated area for 200 mJ laser while it was 1.5 cm for 400 mJ laser. For 200 mJ laser the maximum derived radial (σrr), axial (σzz) and azimuthally (σθθ) stress components were 0.20, 0.16 and 0.08 MPa, respectively. While, for 400 mJ laser the maximum derived σrr, σzz and σθθ stress components were 0.39, 0.31 and 0.16 MPa, respectively. These results confirm that use of 100 μs Er:YAG laser pulses with 500 μs silence at 200 and 400 mJ energies minimizes thermal tissue damage for the laser osteotomies, without continued water cooling (irrigation) on the exposed area.
Language:
English
Published:
Journal of Medical Signals and Sensors, Volume:3 Issue: 4, Oct-Dec 2013
Page:
262
https://magiran.com/p1204140  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!