Inaccuracy of Thyroid to Background Uptake Ratio in Evaluating Technetium-99m-pertechnetate Thyroid Uptake and Establishing an Improved Algorithm

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Objective(s)
The aim of this study was to explore the accuracy of thyroid to background uptake ratio (UR) in the evaluation of 99mTc-pertechnetate thyroid uptake (TcTU) and establishment of an improved algorithm.
Methods
This study was conducted on the thyroid images of 322 patients with thyroid diseases and 67 controls. For the purpose of the study, URs of the images were calculated, and then corrected by standardized thyroid area size to establish a corrected uptake ratio (CUR). Subsequently, the accuracy between UR and CUR was compared.
Results
The results of linear regression using weighted least squares (using TcTU as a dependent variable and CUR, UR, or thyroid area size as independent variables) showed that CUR (t=105.5, P=0.000), UR (t=31.9, P=0.000), and thyroid area size (t=15.9, P=0.000) are influential factors of TcTU. Furthermore, the standardized coefficient of CUR (β=0.983) was obviously higher than those of UR (β=0.851) and thyroid area size (β=0.629). The linear goodness-of-fit between CUR and TcTU (R=0.983) was better than that between UR and TcTU (R=0.851). In addition, the total concordance rate between CUR and TcTU (96.7%) was significantly higher than that between UR and TcTU (83.0%; χ2=42.9, P=0.000). Discordance rates of CUR in large thyroid area (1.4% vs. 13.4%, χ2=17.0, P=0.000) and small thyroid area (3.3% vs. 42.2 %, χ2=44.3, P=0.000), were significantly lower than that of UR. In the abnormal thyroid areas, the discordance rates of UR obviously increased as compared to those of CUR. The UR overestimated the thyroid uptake in small thyroid areas and underestimated it in large thyroid areas.
Conclusion
Based on the findings, CUR is more accurate than UR in measuring 99mTcO4ˉ thyroid uptake; accordingly, it is more significant in the diagnosis of thyroid disease.
Language:
English
Published:
Asia Oceania Journal of Nuclear Medicine & Biology, Volume:7 Issue: 2, Spring 2019
Pages:
160 to 171
https://magiran.com/p2000011  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!