Validity of Three Formulas for Measuring Endotracheal Tube Insertion Depth in Children under Mechanical Ventilation

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background
In the process of intubation, inappropriate placement of the endotracheal tube can lead to hypoxemia, aspiration, insufficient ventilation, atelectasis, barotrauma and pneumothorax. The above complications may be difficult for a patient with severe disease to tolerate; especially when inappropriate placement is not detected by the specialist in the initial evaluation and the diagnosis lasts until the confirmatory chest x-ray is performed. This study evaluated the validity of three formulas in measuring the depth of endotracheal intubation in children under mechanical ventilation.
Methods
60 intubated children aged 2 months to 12 years were included in this study. The patients were randomly divided into three study groups. Endotracheal tube length for each patient was calculated on the basis of the endotracheal tube length formulas (12 + age (years) / 2; endotracheal tube diameter * 3; and 5 + height (cm) / 10). The ideal depth of the endotracheal tube based on chest x-ray was measured as the median distance between the first thoracic vertebra (T1) and the carina in cm. The distance between the ideal depth of the endotracheal tube and the end location of the endotracheal tube was also measured and recorded.
Results
The mean age of the patients was 42.90 months and 58.3% of them were boys. The most common indication for intubation was pneumonia, along with respiratory distress (33.3%). Considering the difference in endotracheal tube depth between the two values calculated using the formula and chest X-ray equal to± 0.5 cm, formula 12 + (2 / age) in 55% of patients, formula 3 * endotracheal tube length in 70% patients and formula 5 + (10 / height) in 85% of patients, were correctly estimated endotracheal tube length. On the other hand, it was observed that in 15%, 45% and 40% of the patients, the formula predicted the correct length of the endotracheal tube for correct intubation without any difference while compared to the chest X-ray. In evaluating the results obtained from the formula and length of the endotracheal tube measured by chest X-ray, it was also observed that the formulas 12 + (2 / age), 3 * length of the endotracheal tube and 5 + (10 / height) were significantly correlated with CXR.
Conclusion
According to the obtained results, it can be concluded that the formulas used to estimate the depth of endotracheal tube placement in children have low accuracies compared to the gold standard of measurement (chest X-ray). Of course, in comparison to the three formulas (height, weight and diameter of the ETT), the height formula was more accurate than others.
Language:
English
Published:
International Journal of Pediatrics, Volume:11 Issue: 111, Mar 2023
Pages:
17463 to 17469
magiran.com/p2557662  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!