Impact of Dose Calculation Algorithms and Radiobiological Parameters on Prediction of Cardiopulmonary Complications in Left Breast Radiation Therapy
Author(s):
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background
Breast cancer requires evaluating treatment plans using dosimetric and biological parameters. Considering radiation dose distribution and tissue response, healthcare professionals can optimize treatment plans for better outcomes.Objective
This study aimed to evaluate the effects of the different Dose Calculation Algorithms (DCAs) and Biologically Model-Related Parameters (BMRPs) on the prediction of cardiopulmonary complications due to left breast radiotherapy.Material and Methods
In this practical study, the treatment plans of 21 female patients were simulated in the Monaco Treatment Planning System (TPS) with a prescribed dose of 50 Gy in 25 fractions. Dose distribution was extracted using the three DCAs [Pencil Beam (PB), Collapsed Cone (CC), and Monte Carlo (MC)]. Cardiopulmonary complications were predicted by Normal Tissue Complication Probability (NTCP) calculations using different dosimetric and biological parameters. The Lyman-Kutcher-Burman (LKB) and Relative-Seriality (RS) models were used to calculate NTCP. The endpoint for NTCP calculation was pneumonitis, pericarditis, and late cardiac mortality. The ANOVA test was used for statistical analysis.Results
In calculating Tumor Control Probability (TCP), a statistically significant difference was observed between the results of DCAs in the Poisson model. The PB algorithm estimated NTCP as less than others for all Pneumonia BMRPs. Conclusion
The impact of DCAs and BMRPs differs in the estimation of TCP and NTCP. DCAs have a stronger influence on TCP calculation, providing more effective results. On the other hand, BMRPs are more effective in estimating NTCP. Consequently, parameters for radiobiological indices should be cautiously used s to ensure the appropriate consideration of both DCAs and BMRPs.Keywords:
Language:
English
Published:
Journal of Biomedical Physics & Engineering, Volume:14 Issue: 2, Mar-Apr 2024
Pages:
129 to 140
https://magiran.com/p2700388
مقالات دیگری از این نویسنده (گان)
-
Collapsed Cone Superposition Algorithm Validation for Chest Wall Tangential Fields using Virtual Wedge Filters
Ahad Zeinali, *, Samaneh Ganjgahi, Hassan Saberi
Journal of Medical Signals and Sensors, Jul-Sep 2023 -
Measuring the leakage dose of TiGRT Dynamic MLC with EDGE diode dosimeter and EBT3 radiochromic film and comparing the results with BEAMnrc code calculations
, Ahad Zeinali, Mostafa Robatjazi, Ghazale Geraily *
Iranian Journal of Radiation Safety and Measurement,