A comparison of the detail reproduction of three type of irreversible hydrocolloid

Author(s):
Message:
Abstract:
Introduction
With due attention to great application of irreversible hydrocolloid impression material in treatment dentistry and importance accuracy of impression in final result of treatment was necessary to study the all of effect factors on the accuracy impression. So this study was done for comparison of surface detail reproduction some of the kinds of irreversible hydrocolloid.
Materials And Methods
In this laboratorial experimental study, was used the recommended laboratoril model of the standard (Iran) and research organization, with the registration number 2787. The form of this model was a stainless steel slotted block in 20, 50 and 75 sizes. The impression materials that used were Super Iralgin, Iralgin and Bayer irreversible hydrocolloid. For each materials was take 20 impression in the same conditions and was poured with type III gypsum and totally 60 cast models was earned. These models were observed with steriomicroscope randomly and each of the identical lines 20, 50 and 75 were allowed with a specific score. For evaluation of the results was used statistic analysis of Mann-Whitney Test and Kruskal Wallis(a = 0.05).
Results
In registration of 20-line, 20 samples of Super Iralgin had sore 3, 19 samples of Regular Iralgin and Alginoplast had score3 and 1 sample score 4. The difference among these 3 groups was not significant (p value = 0.601). In registration of 50-line, 15 samples of Super Iralgin had score 2 and 5 samples had score 3, 7 samples of Alginoplast, had score 2, 13 samples had score 3, 6 samples of in Regular Iralgin had score 2 and 14 samples had score 3.The difference among these 3 groups was significant (p value = 0.008). In registration of 75-line, 15 samples of Super Iralgin had score 1 and 5 samples had score 2, 7 samples of Aliginoplast score 1 and 13 samples had score 2, 6 samples of Regular Iralgin had score 1 and 14 samples had score 2. The difference among these 3 groups was significant (p value = 0.008).
Conclusion
In registration each three lines, the super Iralgin was more precises than the other types and was an ideal impression material. In registration of 20-line, Regular Iralgin and Alginoplast were in the same level, but in registration two others lines, Alginoplast was more precise.It is better to advise to the factory necessary recommendations to improve the quality of the Regular Iralgin material.
Language:
Persian
Published:
Journal of Isfahan Dental School, Volume:4 Issue: 1, 2008
Page:
8
magiran.com/p596673  
دانلود و مطالعه متن این مقاله با یکی از روشهای زیر امکان پذیر است:
اشتراک شخصی
با عضویت و پرداخت آنلاین حق اشتراک یک‌ساله به مبلغ 1,390,000ريال می‌توانید 70 عنوان مطلب دانلود کنید!
اشتراک سازمانی
به کتابخانه دانشگاه یا محل کار خود پیشنهاد کنید تا اشتراک سازمانی این پایگاه را برای دسترسی نامحدود همه کاربران به متن مطالب تهیه نمایند!
توجه!
  • حق عضویت دریافتی صرف حمایت از نشریات عضو و نگهداری، تکمیل و توسعه مگیران می‌شود.
  • پرداخت حق اشتراک و دانلود مقالات اجازه بازنشر آن در سایر رسانه‌های چاپی و دیجیتال را به کاربر نمی‌دهد.
In order to view content subscription is required

Personal subscription
Subscribe magiran.com for 70 € euros via PayPal and download 70 articles during a year.
Organization subscription
Please contact us to subscribe your university or library for unlimited access!