a. fatehi
-
Scientia Iranica, Volume:29 Issue: 6, Nov-Dec 2022, PP 2773 -2788In this paper, for the first time, the combination of these two concepts is used for the earthquake acceleration wave. For this purpose, eight earthquakes from four different locations in the world have been selected. Initially, each earthquake is filtered up to 5 stages using a discrete wavelet transform. Due to the close approximation of the frequency content of the wave to the original earthquake, the approximate wave is used for subsequent calculations. In the next stage, the spectrum of Fourier and the diagram of five of the frequency of dominant of the earthquake are plotted. Also, using the continuous wavelet transform, the time-frequency curves of the main earthquakes and the time-frequency curves of the wave obtained from the discrete wavelet transform are investigated. The goal is to find the best stage of a discrete wavelet filter based on frequency content to reduce computations to over 80%. In the next step, the study examines the time of the strong ground motion, the structure response of single degree of freedom, and the dynamical response of the timing of the structure of a degree of freedom. By examining the above parameters, the best-performing wavelet transformation step is inferred.Keywords: wavelet transform, Frequency content, Fourier spectrum, earthquake
-
بهبود و بهینه کردن روشهای حفاظت در برابر خوردگی از جمله روش حفاظت کاتدی در سالهای اخیر بسیار مورد توجه بوده است. با توجه به پیشرفت علم و فناوری و نیاز صنعت، تکنولوژی ساخت و کنترل یکسوکنندهها نیز پیشرفت چشمگیری نموده است. مشخصههای کاری و راندمان اجزای یکسوکننده طی سالیان متمادی بهبود یافته است. بر پایه مطالعات صورت گرفته، رکتیفایر صنعتی پالسی با قابلیت تولید جریان پالسی در بازه فرکانس 800 هرتز تا 60 کیلوهرتز براساس فرکانس و سیکل کاری مورد نظر با موفقیت طراحی و ساخته شد. جهت بررسی عملکرد حفاظتی این سیستم در شرایط واقعی، رکتیفایر پالسی در کنار رکتیفایر سنتی قرار داده شد و پایش شرایط حفاظتی سیستم پالسی بهطور مستمر در محل ایستگاه، و سه نقطه تست با فواصل مشخص و بهترتیب در فرکانس و سیکل کاری 50 کیلوهرتز و 73 درصد (A)، 60 کیلوهرتز و 73 درصد (B)، 60 کیلوهرتز و 50 درصد (C) و 50 کیلوهرتز و 50 درصد (D) انجام شد. نتایج نشان داد که در سیستم پالسی، مقدار ولتاژ AC نسبت به سیستم سنتی تا بیش از 80% کاهش یافته است. بهعلاوه، مقادیر جریان مصرفی نشان داد که در سیستم پالسی مصرف جریان تا بیش از 70% در مقادیر خاصی از فرکانس و سیکل کاری نسبت به سیستم سنتی کاهش یافته است. با توجه به این که موج پالسی در زمان خاموشی عملا مصرف جریانی ندارد، میتوان بیان کرد که در این حالت مصرف انرژی بهمراتب کاهش مییابد که عامل بسیار مهمی در مصرف انرژی و هزینههای اقتصادی محسوب میشود. بهعلاوه، این دستگاه عملا نیازی به سیستمهای خنککننده رایج ندارد. بر همین اساس، میتوان گفت که سیستم مورد نظر در مقادیر مشخصی از فرکانس و سیکل کاری عملکرد بهتری دارد و استفاده از چنین سیستمهایی در مناطق دارای مقاومت زیاد الکترولیت و بستر آندی را میتوان گزینه مناسبی دانست. همچنین، در صورتی که خط لوله دارای پوشش باشد، حتی با وجود مناطق جدایش پوشش، این سیستم میتواند عملکرد مناسبی داشته باشد. بهعلاوه، پتانسیل حفاظتی (پتانسیل روشن) در طول مدت اندازهگیری و با وجود عملکرد نامناسب بستر آندی، یکنواختتر شده و همچنان در محدوده حفاظت قرار داشت.
کلید واژگان: امپدانس, پوشش جداشده, حفاظت کاتدی, خط لوله فولادی, رکتیفایر پالسیImproving and optimizing corrosion protection methods, including cathodic protection, has received much attention in recent years. Due to the advancement of science and technology and industry development, manufacturing and controlling rectifiers has also made significant progress. The performance characteristics and efficiency of rectifier components have improved over the years. Based on the studies, an industrial pulse rectifier that can produce pulsed current in the frequency range of 800 Hz to 60 kHz based on the desired frequency and duty cycle was successfully designed and manufactured. In order to evaluate the protection performance of this system in the field, the pulse rectifier was placed next to the conventional rectifier, and the protection conditions of the system were continuously monitored. Three test points with specified intervals were analyzed at frequency and duty cycle of 50 kHz and 73% (A), 60 kHz and 73% (B), 60 kHz and 50% (C), and 50 kHz and 50% (D), respectively. Results showed that AC voltage in the pulse system has decreased by more than 80% compared to the conventional system. In addition, the current consumption values showed that in the pulse system, the current consumption has decreased by more than 70% in certain values of frequency and duty cycle. Because the pulse wave has practically no current consumption during off time, energy consumption is greatly reduced, an important factor in energy consumption and economic costs. Also, this system has no cooling system like the conventional rectifiers. Accordingly, the system has a better performance at certain values of frequency and duty cycle. Such systems in areas with high electrolyte resistance can be considered a good option. Also, if the pipeline has a cover, the system can function properly even with the cover separation areas. Moreover, the protection potential became more uniform and remained within the protection range during the measurement period, despite the poor performance of the anode bed.
Keywords: Cathodic protection, Coating disbondment, Steel pipeline, Impedance, pulse rectifier -
در این مقاله، کنترل کننده GPC-fuzzy برای تعیین دوز دارویی و کنترل پیشرفت بیماری HIV براساس مدل ریاضی ارایه شده است. برای این منظور، یک مدل فازی تاکاگی-سوگنو (TS) برای شناسایی رفتار غیرخطی مدل HIV تولید شده است. پارامترهای مدل TS با استفاده از کمترین مربعات خطا تخمین زده میشوند. در این مقاله، سه سناریو برای کنترل بیماری HIV ارایه شده است. در سناریو اول، بر اساس مدل فازی تاکاگی-سوگنو، یک کنترل پیشبینی تعمیم یافته (GPC) برای تعیین دوز دارویی به صورت روزانه طراحی شده است. سناریو دوم و سوم به گونهای طراحی شده اند که برای پیاده سازی عملی همخوانی بیشتری داشته باشند. در سناریو دوم، از آنجاییکه پارامترای بیولوژیکی بیماران متفاوت است، تغییرات در پارامترهای بیولوژیکی در مدلسازی اعمال شده است. در این قسمت محدوده تغییرات پارامترهای ریاضی بدست آورده شده و این تغییرات در مدل ریاضی اعمال شده و در نهایت کنترل کننده پیاده سازی شده است. در سناریو سوم، از آنجاییکه اندازه گیری مقدار سلول های سالم افراد بیمار به صورت روزانه پرهزینه است، فرض شده است ک ه اطالعات سلولهای سالم بیماران به صورت ماهانه در دسترس است و بدین ترتیب دوز دارویی به صورت ماهانه تعیین میشود. بنابراین زمان نمونه برداری خروجی به 30 افزایش یافته و یک سیستم چند نرخه خواهیم داشت. نتایج نشان میدهد که مدل فازی تاکاگی-سوگنو مدل ریاضی بیماری را به خوبی مدل سازی میکند و در همه سناریو ها عملکرد کنترل کننده مناسب است و مقدار سلولهای سالم بر روی میزان قابل قبولی کنترل شده است.
This paper proposes a fuzzy-GPC based on a mathematical model of human immunodeficiency virus (HIV) to determine the drug dosage and control the progression of the illness. For this purpose, a Takagi-Sugeno (TS) fuzzy model is generated to identify the nonlinear behavior of HIV. The parameters of HIV are estimated by the least square error (LSE) estimation method. Moreover, three scenarios are proposed to control HIV. In scenario 1, according to TS fuzzy model, generalized Predictive Control (GPC) is designed for a daily base drug therapy. Scenario 2 and 3 are more practical. In scenario 2, since the biological behavior of patients are different, the variation in the patients biology is taken into account by generating data according to a group of patients with varying parameters in their mathematical model. In senario3, since daily diagnosis of patient’s health is costly, it is assumed that a patient information is available every month, and drug dosage is determined each month. As a result of which, the sample time of the measurement increases to 30 make it a multi-rate system. The result shows that the TS fuzzy models the mathematical model of HIV very well, and in all scenarios, the proposed controller has a good performance and the number of healthy cells are controlled in acceptable amount.
Keywords: Human immunodeficiency virus(HIV), drug dosage, TS fuzzy model, Fuzzy-General Predictive Control(GPC), varying parameters, increasing sample time -
مقدمه
شناسایی علل دخیل در تغذیه برخی شیرخواران با شیر خشک، نقش مهمی در برنامهریزی برای ترویج تغذیه با شیر مادر دارد. هدف مطالعه حاضر تعیین علل مصرف شیر خشک در شیرخواران شهر رفسنجان در سال 1395 بود.
مواد و روشها:
پژوهش توصیفی حاضر بر 372 مادر مراجعهکننده به مراکز بهداشتی درمانی شهر رفسنجان، با فرزندان زیر یک سال که شیر خشک مصرف میکردند انجام شد. از نمونهگیری در دسترس و پرسشنامه محقق ساخته برای جمع آوری اطلاعات استفاده شد. داده ها بر اساس فراوانی، درصد، میانگین و انحراف معیار توصیف شدند.
یافته هامیانگین سن مادران 87/4 ± 61/23 سال و میانگین سن شروع شیر خشک 46/39 ± 71/40 روز بود. مادران با تعداد 208 نفر (9/55 درصد)، بیشترین فراوانی مربوط به عامل شروع کننده مصرف شیر خشک را داشتند. شایع ترین علل این موضوع، تصور ناکافی بودن شیر مادر با 206 نفر (4/55 درصد) و خوب وزن نگرفتن نوزاد با 107 نفر (8/28 درصد) بود.
نتیجهگیری:
نتایج نشان داد مادران نقش مهمی در تغذیه شیرخوار با شیرخشک دارند. شاید به برنامه های آموزشی تقویت کننده باورهای مادران جهت تداوم شیردهی نیاز باشد.
کلید واژگان: شیر مادر, شیرخوار, شیر خشک, رفسنجانIntroductionThis study was conducted to determine the factors related to infant formula milk consumption in Rafsanjan in 2016.
Materials and MethodsThis study was a descriptive study conducted on 372 mothers referred to Rafsanjan health centers with children under one-year-old consuming formula milk. Frequency and percentage were used to describe qualitative data, while mean and standard deviation were used for quantitative variables.
ResultsThe mean age of mothers was 23.61 ± 4.87 years. The mean age of the formula onset was 40.71 ± 39.46 days. 208 mothers (55.9%) had the highest frequency as the initiator of formula milk consumption. The most common causes related to this issue were maternal perceptions of insufficient milk with 206 individuals (55.4%) and poor infant weight gain with 107 individuals (28.8%), respectively.
ConclusionsThe results showed that mothers have a key role in formula milk consumption. Educational programs that strengthen mothers' beliefs may be needed to continue breastfeeding.
Keywords: Breast Milk, Infant, Formula milk, Rafsanjan -
Background
Transcatheter closure of small to moderate patent ductus arteriosus (PDA) has been well established during this last decade. The Amplatzer device occluder (ADO) is a self expandable device with ease of delivery and a rapid learning curve. The aim of the study was to access the optimum sizing of ADO in regard to maximum efficacy with respect to shunt occlusion without oversizing and reducing bulk and potential protrusions.
MethodsFrom April 2007 to July 2008, a total of twenty-four adult PDA closures were reviewed.Occlusion was achieved via antegrade venous approach. Our primary objective was an evaluation of optimum ADO sizing for PDA closures. We retrospectively compared the patients with a theoretical optimum size as regards complications and residual shunts.
ResultsPDA size determination was based on the smallest diameter at pulmonary artery (PA) side.Based on specific criteria, undersizing was not observed in our cases, while oversizing was noted in 42% of cases. Oversizing did not lead to a decrease in residual shunts (37.5% vs. 36%, p=NS). Although no short-term complications were observed in the oversized group, oversizing resulted in a characteristic mushroom deformity due to unnecessary tension applied to our device. The Chinese device also performed well in terms of deployment and short-term complications with no significant difference in comparison to its American counterpart (p=NS).
ConclusionAn acceptable rate of acute complications was obtained; nonetheless, we were frequently oversizing, leading to mild device deformation and protrusion. Although not previously described in the literature, the terminal ballooning of the ADO should alert us of such a complication.
Keywords: Patent ductus arteriosus, AMPLATZER DEVICE OCCLUDER, TRANSCATHETER DEVICE CLOSURE
- در این صفحه نام مورد نظر در اسامی نویسندگان مقالات جستجو میشود. ممکن است نتایج شامل مطالب نویسندگان هم نام و حتی در رشتههای مختلف باشد.
- همه مقالات ترجمه فارسی یا انگلیسی ندارند پس ممکن است مقالاتی باشند که نام نویسنده مورد نظر شما به صورت معادل فارسی یا انگلیسی آن درج شده باشد. در صفحه جستجوی پیشرفته میتوانید همزمان نام فارسی و انگلیسی نویسنده را درج نمایید.
- در صورتی که میخواهید جستجو را با شرایط متفاوت تکرار کنید به صفحه جستجوی پیشرفته مطالب نشریات مراجعه کنید.