Comparison of performance the electro fenton and Fenton process in the removal of hexavalent chromium in presence of cyanide as an intermediate in aqueous
Author(s):
Abstract:
Background And Objectives
The chromium compounds could be hazardous to humans health. The aim of this study was to compare the Performance of Electro- Fenton and Fenton process in the removal of chromium in presence of cyanide as an Intermediate in aqueous.Material &
Methods
In this experimental study, a reactor with 1 liter useful volume was used. Four electrodes made of iron were used in EF. Parameters of study including pH, Voltage, initial concentration of chromium, H2O2 and cyanide as an intermediate in EF process and pH, concentration of Fe ions, initial concentration of chromium, H2O2 and cyanide as an intermediate in F process were examined.Results
The results showed that efficiency of EF process in pH=3, Voltag = 20V in 100 mg/lit chromium, was 97%. Also in F process in optimum condition with pH=3, Fe ions = 500mg/lit, H2O2 = 50ml/lit and chromium concentration = 100 mg/L efficiency was 90%. By cyanide addition reactor efficiency was decreased.Conclusion
EF process outperformed Fenton process in removal of chromium compounds.Keywords:
Electro , Fenton process , Fenton process , chromium , Cyanide , aques
Language:
Persian
Published:
Journal of North Khorasan University of Medical Sciences, Volume:7 Issue: 4, 2016
Pages:
779 to 792
https://magiran.com/p1509117
مقالات دیگری از این نویسنده (گان)
-
The Antibacterial and Catalytic Activity of Iron Magnetite Nanoparticles in the Removal of Ciprofloxacin
Nima Firouzeh, Ali Pasban, Hamed Ghasemzadeh-Moghaddam, Mona Fani, Reza Besharati, Seyedeh Nastaran Asadzadeh*
Journal of Mazandaran University of Medical Sciences, -
Efficacy of Sulfate-based Advanced Oxidation Process (Microwave/Na2S2O8/Fe2+) for 4-Chlorophenol Removal from Aqueous Solutions
Mohammad Malakootian, Mehdi Ghorbanian, Nima Firouzeh, Nastaran Asadzadeh*
Journal of Health Research in Community,