CT Role in the Assessment of Existence of Breast Cancerous Cells

Message:
Article Type:
Research/Original Article (دارای رتبه معتبر)
Abstract:
Background

Application of CT- scanning image information and radiation physical characteristics of the biomaterials are two measurable assays for presenting modified cells.

Objective

This study presented that CT number (HU) and linear attenuation coefficient contain useful information which can be determined during usual CT scanning for the prediction of breast cancerous cells existence based on hemoglobin concentration.

Material and Methods

This experimental study used breast phantom containing major and minor vessels with diameters of 10 and 5 mm, respectively. The major vessels are filled by water, fat, hemoglobin (Hb) as a normal and 4× concentration of hemoglobin (4×Hb) as a cancerous breast cells, then scanned by single slice CT (GE, Hi Speed) 120 kVp, 100 mA for the determination of linear attenuation coefficient (µL).

Results

The CT numbers were for water (-7 to +7 HU), Hb (22±6 HU) and 4×Hb (80±4 HU). The difference between Hb and 4×Hb was significant (p <0.000). Minimum µL was 0.1190±0.00680 cm-1 for fat and maximum was 0.1449±0.00794 cm-1 for 4×Hb.

Conclusion

The study of CT number and linear attenuation coefficient of different concentration of Hb provides a possibility for early predicting of breast cancerous cells existence (4×Hb).

Language:
English
Published:
Journal of Biomedical Physics & Engineering, Volume:10 Issue: 3, May-Jun 2020
Pages:
349 to 356
https://magiran.com/p2141441