A Root Cause Analysis of Haemolysis Encountered in Leuco-filtration of Stored Packed Red Cells Units

Message:
Article Type:
Research/Original Article (بدون رتبه معتبر)
Abstract:
Background and Aims

Leukoreduction of blood components has reduced the incidence of transfusion-associated adverse events. Leucofiltration is the most effective method of leukoreduction. We encountered haemolysis in a series of leucofiltered units. This stressed our precious inventory, added to financial loss, increased our turn-around time to issue leucofiltered blood units, and placed doubts on the safety of our leucofiltered products. A systematic root cause analysis was done to identify the reason for haemolysis.

Materials and Methods

A total of 69 units were leucofiltered during the study period, of which 13 units showed lysis following filtration.

Results

This study warranted a review of our existing leucofiltration standard operating procedures to keep strict adherence to manufacturer instructions to ensure quality in the end product.

Conclusions

Among the leucofiltered units showing hemolysis, 62% were due to higher temperature, 23% due to increased time for filtration, and 15% due to increased holding time of red cell units.

Language:
English
Published:
International Journal of Medical Laboratory, Volume:9 Issue: 1, Feb 2022
Pages:
47 to 54
https://magiran.com/p2408161